STC MSC Roof Panel
STC-MSC Inset Gable Lead Height Change
** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
HEIGHT CHANGE TRIM TOP (GHMTF) INSIDE CLOSURE
* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
* WALL PANEL
BL
HEIGHT CHANGE ANGLE (A-20-H)
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE SUPPORT (A-20-S)
1/4-14 X 1 1/4" WT (12" C.C.)
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
PURLIN STC ROOF PANEL
*** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.
1
4 "
1/4-14 X 1 1/4" SHOULDER (24" C.C.)** HEIGHT CHANGE TRIM BOTTOM (GHMBF)
2"
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)