STC MSC Roof Panel
STC-MSC Inset Gable Height Change w Set Back Field Bend Vertical Leg
** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
*WALL PANEL
BL
SPECIAL HEIGHT CHANGE TRIM TOP (SPT- )
INSIDE CLOSURE
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER
RAKE SUPPORT (A-20-S) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) SPECIAL HEIGHT CHANGE ANGLE (PL- ) #12-14 x 1 1/4"
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
1
4 "
** 1/4-14 X 1 1/4" SHOULDER (24" C.C.)
PURLIN
*** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.
1/4-14 X 1 1/4" WT (12" C.C.) HEIGHT CHANGE TRIM BOTTOM (GHMBF)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)