STC MSC Roof Panel

STC-MSC Inset Gable Tail Height Change w Panel Below

** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PURLIN

INSIDE CLOSURE HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL)

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

RAKE SUPPORT (A-20-S) #12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) * WALL PANEL

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

BL

PURLIN

1/4-14 X 1 1/4" WT (12" C.C.)

***

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

STC/MSC ROOF PANEL

* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

(2) #12-14 X 1 1/4"' PER CLOSURE

HEIGHT CHANGE ANGLE (A-20-H)

1

4 "

TOP VIEW

2"

PURLIN

HEIGHT CHANGE RAFTER RAKE ANGLE (A-20)

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

1/4-14 X 1 1/4" SHOULDER (24" C.C.)**

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

EAVE STRUT

PANELING CAP TRIM (SCT) (2) #12-24 X 1 1/2" AT 36" C.C.

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

1/4-14 X 7/8" (12" C.C.)

*** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker