STC MSC Roof Panel
STC-MSC High Side Height Change w Cee Girt and Panel Below
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) WALL PANEL (TYP.)
INSIDE CLOSURE
BL
(2) #12 - 14 X 1 1/4" (GA) (36" C.C.)
HEIGHT CHANGE GIRT
TRI-BEAD TAPE MASTIC *1/4 - 14 X 7/8" WT HEIGHT CHANGE TRIM (LHET)
**TRI-BEAD TAPE MASTIC OUTSIDE CLOSURE 1/4-14 X 1 1/4" WT (9 PER PANEL) PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)
1
4 "
PRE-GLUED THERMAL SPACER (NOT BY CHIEF) ***
STC/MSC ROOF PANEL
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN BACK - UP PLATE
DRAFTING NOTE: *** Thermal spacer to be used with no insulation. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll. * For screw spacing refer to High Side Height Change detail in the MSC/STC Roof Panel Erection Manual.
4"
8"