STC MSC Roof Panel
STC-MSC High Side Height Change w Cee Girt-Panel Below and Thermal Spacer
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) WALL PANEL (TYP.)
INSIDE CLOSURE
BL
(2) #12-14 X 1 1/4" (GA) (36" C.C.)
HEIGHT CHANGE GIRT
*1/4-14 X 7/8" WT HEIGHT CHANGE TRIM (LHET)
**TRI-BEAD TAPE MASTIC OUTSIDE CLOSURE 1/4-14 X 1 1/4" WT (9 PER PANEL) TRI-BEAD TAPE MASTIC PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)
1
4 "
THERMAL SPACER STC/MSC ROOF PANEL
(NOT BY CHIEF)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
* For screw spacing refer to High Side Height Change detail in the MSC/STC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll.
PURLIN BACK-UP PLATE
4"
8"
Made with FlippingBook flipbook maker