STC MSC Roof Panel

STC-MSC Gable End Field Bend Vertical Leg - Taller Existing Building

1

COUNTER FLASHING (NOT BY CHIEF)

CAULKING (NOT BY CHIEF) SPECIAL TRIM TOP (SPT- ) TRI-BEAD TAPE SEALER SIKA 511 CAULKING IN LOCKFORM OF SPECIAL TRIM TOP (SPT- )(BEFORE ASSEMBLING) (SEE INSET DETAIL) STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION) PRE-GLUED THERMAL SPACER (NOT BY CHIEF) ** 1/4-14 X 1 1/4" WT (12" C.C.)

L EXIST. B

FASTENER AT 12" C.C. (NOT BY CHIEF)

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

RAKE SUPPORT (A-20-S)

** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.

PURLIN

3"

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

RAKE ANGLE (A-20-B) 1/4-14 X 1 1/4" SHOULDER (24" C.C.)*

* IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT AND THAT THESE FASTENERS MUST NOT HIT THE PURLINS.

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)