STC MSC Roof Panel
STC-MSC Eave Gutter and Nichiha Panel Not by Chief
**(2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL 1/4-14 X 1 1/4" WT PANEL TO EAVE (8 PER PANEL)
*TRAPEZOID PLUG (TRP) EACH HIGH RIB TRI-BEAD TAPE MASTIC (TOP AND BOTTOM)
BL
STC/MSC ROOF PANEL 1/4-14 X 1" (2) PER CLOSURE METAL INSIDE CLOSURE #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS
DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM)
X"
GUTTER STRAP (GSM) AT EACH PANEL HI-RIB
EAVE STRUT WALL PANEL
#12-14 X 1 1/4" (TRIM COLOR)
1/4-14 X 7/8" WT (6" C.C.)
SPECIAL TRIM CAP (SPT-X) EAVE GUTTER (EGM)
*** Connection of nichiha panels (not by Chief), to wall panel is not by chief. ** Field cut (2) 2" long strips of tri-bead tape mastic & center under 1/4-14 x 7/8" WT's between gutter strap and roof panel. * See isometric Trapezoid Plug Installation detail for installation instructions.
FASTENER (NOT BY CHIEF) (12" C.C.) SPECIAL PURCHASED (IF BY CHIEF)
*** _" NICHIHA PANEL (NOT BY CHIEF)