Special Features
Parapet at High Side w CS Roof Panel and Nichiha Panel Not by Chief
NOTE: ·
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
Field notch the hems 2" to allow for the trim to lap. Leave a two inch space between the cleats at the connection of the parapet cap trim. Apply a 1/4" bead of Sikalastomer-511 and install 10 blind rivets at each joint.
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
HORIZONTAL LEG OF PARAPET CAP TRIM
·
1
·
BL
PARAPET GIRT SPECIAL PARAPET CAP TRIM (SPT-X) 1/4-14 X 1 1/4" WT (6" C.C.) (TYP) OUTSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.)
X"
X"
#12-14 X 1 1/4" (24" C.C.)
SPECIAL PARAPET CAP TRIM (SPT-X) (OVERLAPPING)
XXX'-X"
#12 - 14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
SPECIAL PARAPET CLEAT (SPT-X)
SIKA-511
BACKUP PANEL INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM HEIGHT CHANGE TRIM (LHTC) 1/4-14 X 7/8" WT (12" C.C.) OUTSIDE CLOSURE (2" X 3') 2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
SPECIAL PARAPET CAP TRIM (SPT-X) (UNDER LAPPING)
PANCAKE HEAD FASTENER (NOT BY CHIEF)(12" C.C.)
2"
SPECIAL PURCHASED (IF BY CHIEF)
2"
1"
* _" NICHIHA PANEL (NOT BY CHIEF)
XXX'-X"
2" GAP
SPECIAL PARAPET CLEAT (SPT-X)
CS PANEL
1
4 "
PARAPET/WALL PANEL HEIGHT CHANGE GIRT
1 1
2 "
SPECIAL PARAPET CLEAT (SPT-X)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
EAVE STRUT 1/4 -14 X 1 1/4" WT (6" C.C.)
1/4-14 X 1 1/4" WT (6" C.C.) PURLIN
ISOMETRIC PARAPET / FACADE CAP TRIM SPLICE DETAIL
DRAFTING USE ONLY: REMOVE EAVE STRUT OR PURLIN W/CORRESPONDING FASTENER AS REQ'D .
* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF.