Special Features
Parapet at Low Side w Multi-gutter and Nichiha Panel Not by Chief
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
1
* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
BL
HORIZONTAL LEG OF PARAPET CAP TRIM
SPECIAL PARAPET CAP TRIM (SPT-X) * SPECIAL PARAPET CLEAT (SPT-X) #12-14 X 1 1/4" (24" C.C.)
X"
1/4-14 X 7/8" WT (12"C.C) 1/4-14 X 1 1/4" WT (6" C.C.) FACADE GIRT
X
OUTSIDE CLOSURE
XXX'-X"
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4 -14 X 1 1/4" WT (6" C.C.) BACKUP PANEL
PANCAKE HEAD FASTENER (NOT BY CHIEF) (12"C.C)
SPECIAL PURCHASED (IF BY CHIEF)
INSIDE CLOSURE W/MASTIC TOP & BOTTOM
#12-14 X 1 1/4" (CS - 6" C.C.)(AP - 12" C.C.)
XXX'-X"
*** MULTI-GUTTER (MG-X) EAVE STRUT 1/4-14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL
** _" NICHIHA PANEL (NOT BY CHIEF) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PARAPET/WALL PANEL GIRT
*** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps
** NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF.
Made with FlippingBook flipbook maker