Composite Material, Rigid Board, R-Seal

STC-MSC Rigid Roof-Wall Gable Field TT

NOTES: * It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. ** Field cut outside closure for higher roof pitches. *** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system.

RAKE SUPPORT (A-20-S)

*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF) STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION) 1/4-14 X 1 1/4" SHOULDER (24" C.C.) * 1/4-14 X 1 1/4" WT (12" C.C.) RAKE SUPPORT (A-20-S) TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" SHOULDER (24" C.C.) *

TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) 1/4-14 X 7/8" WT (6" C.C.) TRI-BEAD TAPE SEALER

BL

x"

GABLE TRIM (SPT-x)

ROOF PANEL SUPPORT (A-20-L)

(2) 1/4-14 X 7/8"

#12-14 X ____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

INSIDE CLOSURE

**OUTSIDE CLOSURE WALL PANEL 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET)

1/4-14 X ____" W/O (2 EACH PURLIN)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

RAKE ANGLE (A-20)

PURLIN

*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)