Composite Material, Rigid Board, R-Seal
STC-MSC Deck Rigid Roof-Wall Gable Field TT
NOTES: * It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. ** Field cut outside closure for higher roof pitches. *** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. **** See Roof Deck Fastener Details for additional fastener spacing information.
RAKE SUPPORT (A-20-S)
1/4-14 X 1 1/4" SHOULDER (24" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) * 1/4-14 X 1 1/4" WT (12" C.C.) RAKE SUPPORT (A-20-S) TRI-BEAD TAPE SEALER STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) 1/4-14 X 7/8" WT (6" C.C.) TRI-BEAD TAPE SEALER
BL
x"
GABLE TRIM (SPT-x) ROOF PANEL SUPPORT ANGLE (A-20-L)
(2) 1/4-14 X 7/8"
PURLIN
INSIDE CLOSURE
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
#12-14 X _____" (6" C.C. for CS PANEL) (12"C.C. for AP PANEL)
GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) 1/4-14 X 7/8" (12" C.C.) WALL PANEL **OUTSIDE CLOSURE
DECKING
1/4-14 X ____" W/O (2 EACH PURLIN)
PURLIN
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) **** ___ X ___ (2 EACH PURLIN)
*** _____" RIGID BOARD INSULATION (NOT BY CHIEF)
RAKE ANGLE (A-20)