Composite Material, Rigid Board, R-Seal

AP Wall Details Rigid Wall

AP WALL PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.

NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · Special Fastener spacing is (12" C.C.) unless otherwise noted. · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather. Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. X" #12-14 X x" RIGID BOARD INSULATION NOTES: · Special Fastener = · Rigid Continuous insulation thickness = · Rigid Continuous insulation not shown on all details for clarity. ·

12"

Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")

STEEL LINE

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

BL

GIRT

Clip offset

RAKE ANGLE

WALL PANEL

TAPE MASTIC AT SIDELAPS, IF ORDERED

SPECIAL FASTENER (12" C.C.)

TOP OF PURLIN

NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.

SPECIAL FASTENER (12" C.C.)

SPECIAL FASTENER (12" C.C.)

1"

BL

AP PANELING

Intermediate Girt Detail

EAVE STRUT

Eave Height

WALL PANEL

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

BL

STEEL LINE

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

Sidewall Eave Detail Low side shown. High Side Typical.

BL

PANEL SIDELAP EAVE STRUT

GIRT

SPECIAL FASTENER (12" C.C.) (TYP.)

RISE

12" (TYP.)

3" 3"

6"

SPECIAL FASTENER (12" C.C.)

MIN.

WALL PANEL

BL

Panel Endlap Detail

* 1/4-14 X 7/8" (TYP.)

AP PANEL FASTENER INSTALLATION

AP PANEL AT GABLE END

1/4-14 X 7/8" (TYP.) (18" C.C.)

NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.

NOTES: ·

Field cut panel if required for corner trim.

· Corner Angle connection/fasteners, refer to Girt Corner Detail.

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

GIRT

12" (TYP.)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

STEEL LINE

STEEL LINE

AP PANEL PANELING SUPPORT (SSP)

CORNER ANGLE (A-20)

RETURN LEG

STEEL LINE

SPECIAL CORNER TRIM (SPT-x)

OPTIONAL TAPE MASTIC CENTERED ON HIGH RIB (REFER TO DRAWING COVER PAGE FOR WALL MASTIC REQUIREMENTS)

1/4-14 X 7/8" (18" C.C.)

* 18" (TYP.)

PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)

12" (TYP.)

SPECIAL FASTENER (12" C.C.) (TYP.)

2 1/2"

1 1/2"

1/4-14 X 7/8" (12" C.C.) (TYP.) SPECIAL FASTENER (12" C.C.) (TYP.)

BASE MEMBER

TAPE MASTIC AT SIDELAPS, IF ORDERED

AP PANEL INSTALLATION

AP PANEL SIDE LAPS

AP PANEL STANDARD CORNER CONDITION