Composite Material, Rigid Board, R-Seal
CS Wall Details Rigid Wall
CS WALL PANEL WITH RIGID BOARD INSULATION - The details shown below are typical. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.
NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · Special Fastener spacing is (12" C.C.) unless otherwise noted. · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather. Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. X" #12-14 X x" RIGID BOARD INSULATION NOTES: · Special Fastener = · Rigid Continuous Insulation thickness = · Rigid Continuous Insulation not shown on all details for clarity. ·
6"
3"
Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")
STEEL LINE
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
GIRT
BL
Clip offset
WALL PANEL
RAKE ANGLE
TAPE MASTIC AT SIDELAPS, IF ORDERED
SPECIAL FASTENER (12" C.C.)
TOP OF PURLIN
NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.
SPECIAL FASTENER (6" C.C.)
SPECIAL FASTENER (6" C.C.)
1"
BL
CS PANELING
Intermediate Girt Detail
EAVE STRUT
Eave Height
WALL PANEL
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
STEEL LINE
BL
BL
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
Sidewall Eave Detail Low side shown. High Side Typical.
RISE
GIRT
PANEL SIDELAP EAVE STRUT
6" (TYP.)
3"
SPECIAL FASTENER (6" C.C.) (TYP.)
3" 3"
SPECIAL FASTENER (6" C.C.)
6"
WALL PANEL
MIN.
BL
1/4-14 X 7/8" (TYP.) (18" C.C.)
Panel Endlap Detail
CS PANEL FASTENER INSTALLATION
1/4-14 X 7/8" (TYP.)
CS PANEL AT GABLE END
NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.
NOTES: ·
Field cut panel if required for corner trim.
· Corner Angle connection/fasteners, refer to Girt Corner Detail. · Connection of panel to structure at corner is by the corner trim fasteners.
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
GIRT
12" (TYP.)
STEEL LINE
SPECIAL FASTENER (12" C.C.) (TYP.)
STEEL LINE
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
CS PANEL
CORNER ANGLE (A-20)
RETURN LEG
PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)
STEEL LINE
SPECIAL CORNER TRIM (SPT-x)
OPTIONAL TAPE MASTIC CENTERED ON HIGH RIB (REFER TO DRAWING COVER PAGE FOR WALL MASTIC REQUIREMENTS)
* 18" (TYP.)
1/4-14 X 7/8" (18" C.C.)
6" (TYP.)
3"
1/4-14 X 7/8" (TYP.)
SPECIAL FASTENER (6" C.C.) (TYP.)
2 1/2"
1 1/2"
SPECIAL FASTENER (12" C.C.) (TYP.)
BASE MEMBER
CS PANEL INSTALLATION
CS PANEL SIDE LAPS
CS PANEL STANDARD CORNER CONDITION