Composite Material, Rigid Board, R-Seal

CS Wall Details Rigid Wall

CS WALL PANEL WITH RIGID BOARD INSULATION - The details shown below are typical. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.

NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · Special Fastener spacing is (12" C.C.) unless otherwise noted. · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather. Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. X" #12-14 X x" RIGID BOARD INSULATION NOTES: · Special Fastener = · Rigid Continuous Insulation thickness = · Rigid Continuous Insulation not shown on all details for clarity. ·

6"

3"

Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")

STEEL LINE

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

GIRT

BL

Clip offset

WALL PANEL

RAKE ANGLE

TAPE MASTIC AT SIDELAPS, IF ORDERED

SPECIAL FASTENER (12" C.C.)

TOP OF PURLIN

NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.

SPECIAL FASTENER (6" C.C.)

SPECIAL FASTENER (6" C.C.)

1"

BL

CS PANELING

Intermediate Girt Detail

EAVE STRUT

Eave Height

WALL PANEL

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

STEEL LINE

BL

BL

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

Sidewall Eave Detail Low side shown. High Side Typical.

RISE

GIRT

PANEL SIDELAP EAVE STRUT

6" (TYP.)

3"

SPECIAL FASTENER (6" C.C.) (TYP.)

3" 3"

SPECIAL FASTENER (6" C.C.)

6"

WALL PANEL

MIN.

BL

1/4-14 X 7/8" (TYP.) (18" C.C.)

Panel Endlap Detail

CS PANEL FASTENER INSTALLATION

1/4-14 X 7/8" (TYP.)

CS PANEL AT GABLE END

NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.

NOTES: ·

Field cut panel if required for corner trim.

· Corner Angle connection/fasteners, refer to Girt Corner Detail. · Connection of panel to structure at corner is by the corner trim fasteners.

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

GIRT

12" (TYP.)

STEEL LINE

SPECIAL FASTENER (12" C.C.) (TYP.)

STEEL LINE

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

CS PANEL

CORNER ANGLE (A-20)

RETURN LEG

PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)

STEEL LINE

SPECIAL CORNER TRIM (SPT-x)

OPTIONAL TAPE MASTIC CENTERED ON HIGH RIB (REFER TO DRAWING COVER PAGE FOR WALL MASTIC REQUIREMENTS)

* 18" (TYP.)

1/4-14 X 7/8" (18" C.C.)

6" (TYP.)

3"

1/4-14 X 7/8" (TYP.)

SPECIAL FASTENER (6" C.C.) (TYP.)

2 1/2"

1 1/2"

SPECIAL FASTENER (12" C.C.) (TYP.)

BASE MEMBER

CS PANEL INSTALLATION

CS PANEL SIDE LAPS

CS PANEL STANDARD CORNER CONDITION

Made with FlippingBook Annual report maker