Composite Material, Rigid Board, R-Seal

CS Window or 4-Sided Opening w Sill Flashing-WFS Rigid Wall

CS Panel - Rigid Board Insulation in Wall - Window Not by Chief or 4-Sided Opening - with Sill Flashing – WFS

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Rigid Continuous Insulation.

2" JAMB TRIM NOTCH

3. Sill Trim Flashing (SPT), slit and fold up at jamb. 4. Liner Cover Trim (outer LCT at Building Line). 5. Jamb Trim (JT) with notch at header. 6. Header Trim (HTT). 7. Notch and slit wall panel. 8. Place wall panel over trims with foam inside closures. 9. Cover Trim (COT). 10.Liner Cover Trim (inner LCT used with Liner/Backer, if applicable.) 11.Refer to Liner or Partition Panel Drawings.

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

HEADER TRIM (HTT)

JAMB TRIM (JT) INSIDE CLOSURE

SPECIAL JAMB TRIM (SPT-x)

1" SLIT

2" X 1/4" NOTCH

Notes: ·

LINER COVER TRIMS

Special Fastener =

#12-14 X ____"

2" JAMB TRIM NOTCH

·

Rigid Continuous Insulation thickness =

X"

FIELD VERIFY SPT OFFSET

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown below are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

3" TO FLAT OF JAMB TRIM

WALL PANEL SLIT

COVER TRIM (COT)

NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) SPECIAL FASTENER (6" C.C.) WALL PANEL SPECIAL SILL TRIM FLASHING (SPT-x) 1/8" X 3/8" BLIND RIVET (12" C.C.)

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

TRIM DETAIL AT CORNERS

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)

BL

#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

ZEE GIRT

OPENING WIDTH

LINER COVER TRIM (LCT1) (AS REQUIRED)

OPENING WIDTH

SPECIAL FASTENER (6" C.C.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH COVER TRIM (LCT) LINER COVER TRIM (LCT1) (AS REQUIRED) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

INSIDE CLOSURE

JAMB

* 1 4 "

WRB TAPE OR BUTYL SEALANT AROUND

HEADER TRIM (HTT)

PENETRATIONS (NOT BY CHIEF)

JAMB

(2) 1/8" X 3/8" BLIND RIVET (3'-0" C.C.)

LINER COVER TRIM (LCT1) (2) 1/8" X 3/8" BLIND RIVET (3'-0" C.C.)

BL

BL

LINER COVER TRIM (LCT1)

OPENING

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

CEE HEADER

SPECIAL FASTENER (12" C.C.) WALL PANEL RIGID CONTINUOUS INSULATION (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

JAMB TRIM (JT)

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH COVER TRIM (LCT)

CUT RIB AS NEEDED 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)

SILL TRIM FLASHING (WFS) INSIDE CLOSURE SPECIAL FASTENER (6" C.C.)

GIRT/SILL

COVER TRIM (COT)

1/8" X 3/8" BLIND RIVET (12" C.C.)

WALL PANEL (TYP.)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAIL AT JAMB

OPTIONAL FRAMED OPENING DETAIL AT JAMB (Optional detail for increased weathertightness (Not by Chief))