Composite Material, Rigid Board, R-Seal
CS Window or 4-Sided Opening w Jamb Trim-JT Rigid Wall
CS Panel - Rigid Board Insulation in Wall - Window Not by Chief or 4-Sided Opening - with Sill Jamb Trim – JT
Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer.
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
Refer to Liner or Partition Panel Drawings. 3. Special Sill, Special Jamb Trim (SPT). 4. Rigid Continuous Insulation. 5. Jamb Trim (JT) with notch at header. 6. Header Trim (HTT). 7. Notch and slit wall panel. 8. Place wall panel over trims with foam inside closures full width of header. 9. Cover Trim (COT).
1" PANEL SLIT
HEADER TRIM (HTT)
INSIDE CLOSURE JAMB TRIM (JT)
1" SLIT
2" X 1/4" NOTCH
SPECIAL JAMB TRIM (SPT-x)
Notes: ·
2" JAMB TRIM NOTCH
LINER COVER TRIMS
#12-14 X ____"
Special Fastener =
For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
X"
·
Rigid Continuous Insulation thickness =
SIKA-511
· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown below are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT
3" TO FLAT OF JAMB TRIM
OPTIONAL JAMB TRIM FOLD UP
COVER TRIM (COT)
NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) SPECIAL FASTENER (6" C.C.) WALL PANEL SPECIAL SILL JAMB TRIM (SPT-x)
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
TRIM DETAIL AT CORNERS
#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
ZEE GIRT
BL
SPECIAL FASTENER (6" C.C.) #12-14 X 1" PANCAKE HEAD (12" C.C.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) JAMB
OPENING WIDTH
CEE HEADER
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
LINER COVER TRIM (LCT1)
INSIDE CLOSURE
* 1 4 "
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
HEADER TRIM (HTT)
SPECIAL JAMB TRIM (SPT-x)
LINER COVER TRIM (LCT2)
#12-14 X 1" PANCAKE HEAD (12" C.C.)
LINER COVER TRIM (LCT1)
BL
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
LINER COVER TRIM (LCT2)
OPENING
SPECIAL JAMB TRIM (SPT-x)
SPECIAL FASTENER (12" C.C.) WALL PANEL RIGID CONTINUOUS INSULATION (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
JAMB TRIM (JT)
SILL SILL JAMB TRIM (SPT-x) INSIDE CLOSURE SPECIAL FASTENER (6" C.C.)
GIRT/SILL
CUT RIB AS NEEDED 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)
#12-14 X 1" PANCAKE HEAD (12" C.C.)
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
COVER TRIM (COT)
WALL PANEL (TYP.)
OPENING DETAILS AT HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
Made with FlippingBook Annual report maker