Eave and Gable Extensions

MVF-MVP Gable Ext Tail End w AP Soffit and Thermal Spacer

* NOTE: This fastener must not hit the purlin.

CLIP LOCATION FROM SL ROOF PANEL CUT BACK DIMENSION

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

GABLE EXTENSION DIMENSION

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN

PURLIN CLOSURE (TYP.)

BL

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) * 1/4-14 X 1 1/4" WT (6" C.C.) DOUBLE BEAD TAPE MASTIC DOUBLE BEAD TAPE MASTIC PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION

GABLE TRIM (GTVC)

PRE-GLUED THERMAL SPACER

(NOT BY CHIEF)

1 3 4 "

MVF/MVP ROOF PANEL PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN) PURLIN CLOSURE (GPC)

RAKE ANGLE (A-20-B) (2) #12-14 X 1 1/4"(WALL COLOR) EACH CLIP

1"

PURLIN

#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) (2) 1/4-14 X 7/8" PANEL CLIP w/FASTENERS EXTENSION FLASHING (EF) PANEL SUPPORT TRIM (SSP) #12-14 X 1" PANCAKE HEAD EACH PURLIN 1/4-14 X 7/8" (12" C.C.)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

(NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

TOP VIEW

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

AP SOFFIT PANEL JAMB TRIM (JT)

1/4-14 X 7/8" (12" C.C.) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) #12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) PANEL SUPPORT TRIM (SSP)

EAVE STRUT

INSIDE CLOSURE **

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

RAKE ANGLE (A-20-B) WALL PANEL

** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker