Eave and Gable Extensions
LS Eave Ext Only - Horiz FSP Soffit Bypass Gable and Standing Seam Roof Panel Low Pitch
REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE.
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
CUT THIS SECTION AT END OF EXTENSION GABLE EXTENSION CHANNEL (GEC) XLGA-1 CLIP
#12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) GABLE EXTENSION CHANNEL (GEC) INSIDE CLOSURE *
STC/MSC ROOF: (2) #12-14 X 1" PANCAKE HEAD AT PURLINS MVF/MVP ROOF: (2) #12-14 X 1 1/4" AT PURLINS (WALL COLOR )
1
1
EAVE EXTENSION PURLIN (FIELD NOTCH FOR SPECIAL CHANNEL) (2) #12-14 X 1 1/4" (WALL COLOR) #12-14 X 1" PANCAKE HEAD (24" C.C.) (2) #12-14 X 1" PANCAKE HEAD
BL
INTERMEDIATE PURLIN
BL
FRAMING CONDITION NOT SHOWN
EAVE EXTENSION END PANEL #12-14 X 1" PANCAKE HEAD (24" C.C.)
INSIDE CLOSURE **
SOFFIT RAKE ANGLE (A-20)
XXX' - X"
1
4 "
EAVE EXTENSION BEAM FSP SOFFIT PANEL #12-14 X 1" PANCAKE HEAD (12" C.C) (TYP.)
SOFFIT TRIM (VPST)
EAVE EXTENSION BEAM
1/8" X 3/8" BLIND RIVET (12" C.C.) PANEL SUPPORT (SSSP) * DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
(4) 1/2" X 1 1/4" BOLTS
XBC-33
SOFFIT RAKE ANGLE (A-20) #12-14 X 1" PANCAKE HEAD
Made with FlippingBook flipbook maker