Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit Bypass Gable and Standing Seam Roof Panel Low Pitch

REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE.

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

CUT THIS SECTION AT END OF EXTENSION GABLE EXTENSION CHANNEL (GEC) XLGA-1 CLIP

#12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) GABLE EXTENSION CHANNEL (GEC) INSIDE CLOSURE *

STC/MSC ROOF: (2) #12-14 X 1" PANCAKE HEAD AT PURLINS MVF/MVP ROOF: (2) #12-14 X 1 1/4" AT PURLINS (WALL COLOR )

1

1

EAVE EXTENSION PURLIN (FIELD NOTCH FOR SPECIAL CHANNEL) (2) #12-14 X 1 1/4" (WALL COLOR) #12-14 X 1" PANCAKE HEAD (24" C.C.) (2) #12-14 X 1" PANCAKE HEAD

BL

INTERMEDIATE PURLIN

BL

FRAMING CONDITION NOT SHOWN

EAVE EXTENSION END PANEL #12-14 X 1" PANCAKE HEAD (24" C.C.)

INSIDE CLOSURE **

SOFFIT RAKE ANGLE (A-20)

XXX' - X"

1

4 "

EAVE EXTENSION BEAM FSP SOFFIT PANEL #12-14 X 1" PANCAKE HEAD (12" C.C) (TYP.)

SOFFIT TRIM (VPST)

EAVE EXTENSION BEAM

1/8" X 3/8" BLIND RIVET (12" C.C.) PANEL SUPPORT (SSSP) * DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

(4) 1/2" X 1 1/4" BOLTS

XBC-33

SOFFIT RAKE ANGLE (A-20) #12-14 X 1" PANCAKE HEAD

Made with FlippingBook flipbook maker