Eave and Gable Extensions

CS Gable Ext FSP Soffit

CS ROOF PANEL FOR ANGLE TO PURLIN AND SOFFIT TO ANGLE WILL BE SENT. CHANGE ANGLE AND FASTENERS TO "DIM" LAYER. IF SUB-FRAMING AT GABLE EXTENSION EXCEEDS 4'-0 SPACING THEN AN A-20 ANGLE WILL BE SENT AND FIELD CUT AROUND PURLINS FOR ATTACHMENT. FASTENERS

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

1

* FIELD CUT AROUND PURLINS FOR ATTACHMENT.

PURLIN CLOSURE (TYP.)

BL

GABLE EXTENSION DIMENSION

1/4-14 X 7/8" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC #12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)

2 1 8 "

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1 1/4" (2 PER PURLIN) (WALL COLOR) 1/4-14 X 7/8" (12" C.C.) GABLE TRIM (GTC)

PURLIN

PURLIN

PURLIN CLOSURE (GPC)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

(2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

* RAKE ANGLE (A-20)

(2) #12-14 X 1 1/4"' PER CLOSURE

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED)

TOP VIEW

1"

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE

GABLE EXTENSION CHANNEL (GEC)

#12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION) (TYP.) EXTENSION FLASHING (EF)

1/4-14 X 7/8" (EACH RIB)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

JAMB TRIM/SOFFIT TRIM (JTS) 1/8" X 3/8" BLIND RIVET(12" C.C.) #12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION) #12-14 X 1" PANCAKE HEAD (12" C.C.)

RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PANEL CAP TRIM (SCT) WALL PANEL 1/4-14 X 7/8" (12" C.C.) INSIDE CLOSURE **

FSP SOFFIT PANEL

EAVE STRUT

1/8" X 3/8" BLIND RIVET (12" C.C.)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

NOTE: 26 GA FSP SOFFIT MUST ALWAYS HAVE 1/4-14 X 7/8" FASTENERS LOCATED AT RIBS AT END SUPPORTS. CHANGE FASTENERS TO "DIM" LAYER.

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker