Eave and Gable Extensions
CS Gable Ext Roof Panel Starts Outside Building Line AP Soffit
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
1
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
* DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
GABLE TRIM (GTC)
CLOSURE CLIPS (GCC-1) (TYP.)
GABLE EXTENSION DIMENSION
PURLIN CLOSURE (TYP.)
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) 1/4-14 X 7/8" (12" C.C.) #12-14 X 1 1/4" (2 PER PURLIN) (WALL COLOR)
BL
2 1 8 "
#12-14 X 1" PANCAKE HEAD EACH PURLIN DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (12" C.C.)
?
PURLIN
1"
PURLIN CLOSURE (GPC)
PURLIN
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED) (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
CS ROOF PANEL
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
GABLE EXTENSION CHANNEL (GEC)
(2) #12-14 X 1 1/4"' PER CLOSURE
EXTENSION FLASHING (EF)
TOP VIEW
(2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE
#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) PANEL SUPPORT (SSP) 1/4-14 X 7/8" (12" C.C.)
AP SOFFIT PANEL
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)
INSIDE CLOSURE *
1/4-14 X 7/8" (12" C.C.) PANEL SUPPORT TRIM (SSP)
RAKE ANGLE (A-20-B) 1/4-14 x 7/8" (12" C.C.)
EAVE STRUT
JAMB TRIM (JT)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PANEL CAP TRIM (SCT)
WALL PANEL
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker