Eave and Gable Extensions
CS Gable Ext Roof Panel Starts Outside Building Line CS Soffit
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
* DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
1
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
GABLE EXTENSION DIMENSION
BL
1/4-14 X 7/8" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC
2 1 8 "
1/4-14 X 7/8" (12" C.C.) GABLE TRIM (GTC) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1 1/4" (2 PER PURLIN) (WALL COLOR)
?
PURLIN CLOSURE (GPC)
CS ROOF PANEL
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED) (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
PURLIN
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
1"
(2) #12-14 X 1 1/4"' PER CLOSURE
TOP VIEW
GABLE EXTENSION CHANNEL (GEC)
(2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE
CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1" PANCAKE HEAD EACH PURLIN
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
EXTENSION FLASHING (EFC)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
JAMB TRIM (JT)
#12-14 X 1 1/4" (12" C.C.)
INSIDE CLOSURE *
1/4-14 X 7/8" (12" C.C.)
EAVE STRUT
RAKE ANGLE (A-20-B) PANEL CAP TRIM (SCT) WALL PANEL
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker