Eave and Gable Extensions
CS Gable Ext Roof Panel Starts Outside Building Line NO Soffit
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
1
PURLIN CLOSURE (TYP.)
GABLE EXTENSION DIMENSION
BL
2 1 8 "
1/4-14 X 7/8" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC
?
PURLIN CLOSURE (GPC) #12-14 X 1" PANCAKE HEAD (EACH PURLIN)
GABLE TRIM (GTC)
#12-14 X 1 1/4" (2 PER PURLIN) (WALL COLOR) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
PURLIN
CS ROOF PANEL
PURLIN
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN * DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
(2) #12-14 X 1 1/4"' PER CLOSURE
1"
* INSIDE CLOSURE
TOP VIEW
GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.)
PANEL CAP TRIM (SCT) 1/4-14 X 7/8" (12" C.C.) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
EXTENSION FLASHING (EF)
#12-14 X 1" PANCAKE HEAD EACH PURLIN #12-14 X 1 1/4" (12" C.C.)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
WALL PANEL
RAKE ANGLE (A-20-B) FIELD NOTCH AS REQUIRED AT EACH PURLIN ROW
EAVE STRUT
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker