Eave and Gable Extensions

STC-MSC Gable Ext Tail End-Field Bend Vertical Leg w AP Soffit

* NOTE: It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF) PRE-GLUED THERMAL SPACER *** (NOT BY CHIEF)

PURLIN

NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

GABLE EXTENSION DIMENSION

PURLIN CLOSURE (TYP.)

BL

GABLE TRIM (GTMC)

STC/MSC ROOF PANEL #12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)

#12-14 X 1" PANCAKE HEAD EACH PURLIN) EXTENSION FLASHING (EF) PANEL SUPPORT TRIM (SSP) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-S) GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) (2) 1/4-14 X 7/8"

PURLIN CLOSURE (GPC)

PURLIN

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN) #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

PURLIN

(2) #12-14 X 1 1/4"' PER CLOSURE

TOP VIEW

AP SOFFIT PANEL

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

PANEL SUPPORT TRIM (SSP) 1/4-14 X 7/8" (12" C.C.)

EAVE STRUT

INSIDE CLOSURE **

JAMB TRIM (JT)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

1/4-14 X 7/8" (12" C.C.)

***DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

PURLIN CLOSURE INSTALLATION

WALL PANEL