Eave and Gable Extensions
STC-MSC Gable Ext Tail End-Field Bend Vertical Leg w CS Soffit
* NOTE: It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF) PRE-GLUED THERMAL SPACER *** (NOT BY CHIEF)
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
GABLE EXTENSION DIMENSION TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12"C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.)
BL
GABLE TRIM (GTMC)
1/4-14 X 7/8" (12" C.C.) GABLE EXTENSION CHANNEL (GEC) EXTENSION FLASHING (EFC) #12-14 X 1" PANCAKE HEAD EACH PURLIN #12-14 X 1 1/4" (12" C.C.) GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) RAKE SUPPORT (A-20-S) (2) 1/4-14 X 7/8"
PURLIN
PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN)
STC/MSC ROOF PANEL
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
PURLIN
PURLIN CLOSURE (GPC)
(2) #12-14 X 1 1/4"' PER CLOSURE
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
TOP VIEW
CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JT) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
EAVE STRUT
INSIDE CLOSURE **
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
RAKE ANGLE (A-20-B)
***DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
WALL PANEL
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker