Eave and Gable Extensions

STC-MSC Gable Ext Tail End -Term Trim w FSP Soffit and Thermal Spacer

DRAFTING NOTES: *** Inside closure must be provided on buildings with liner insulation system. **** 26 GA FSP soffit must always have 1/4-14 x 7/8" fasteners located at ribs at end supports. change fasteners to "dim" layer.

***** If sub-framing at gable extension exceeds 4'-0 spacing then an A-20 angle will be sent and field cut around purlins for attachment. Fasteners for angle to purlin and soffit to angle will be sent. Change angle and fasteners to "dim" layer.

PURLIN

*****

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

GABLE EXTENSION DIMENSION

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

1/4-14 X 1 1/4" WT (24" C.C.)

TRI-BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP) TERMINATION TRIM (GTTM) RAKE SUPPORT (A-20-T) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION

TRI-BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)

PANEL CLIP w/FASTENERS (TYP) PURLIN STC/MSC ROOF PANEL

GABLE TRIM (GTM)

PURLIN

#12-14 x 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

(NOT BY CHIEF)

THERMAL SPACER

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

PURLIN CLOSURE (GPC)

(2) #12-14 X 1 1/4"' PER CLOSURE

#12-14 x 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 x 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

(2) 1/4-14 X 7/8"

(NOT BY CHIEF)

TOP VIEW

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

****

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

GABLE EXPANSION TRIM (GET)

1/4-14 X 7/8" (12" C.C.)

#12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION) EXTENSION FLASHING (EF) FSP SOFFIT PANEL 1/8" X 3/8" BLIND RIVET (12" C.C.) GABLE EXTENSION CHANNEL (GEC)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/8" X 3/8" BLIND RIVET (12" C.C.) #12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION) (TYP.) JAMB TRIM/SOFFIT TRIM (JTS) #12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)

EAVE STRUT

INSIDE CLOSURE ***

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

** RAKE ANGLE (A-20)

WALL PANEL

PURLIN CLOSURE INSTALLATION

* It is important that 1/4-14 x 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.

** Field cut around purlins for attachment.

Made with FlippingBook flipbook maker