High Profile Trim
STC-MSC Gable Ext Tail End High Profile Trim-Term Trim CS Soffit and Thermal Spacer
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
GABLE EXTENSION DIMENSION
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
BL
* It is important that 1/4-14 x 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.
TRI-BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.) #12-14 X 1" PANCAKE HEAD EACH PURLIN (NOT BY CHIEF) PRE-GLUED THERMAL SPACER
TRI-BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.) RAKE SUPPORT (A-20-T) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) GABLE TRIM (GTMH)
STC/MSC ROOF PANEL PANEL CLIP w/FASTENERS
?
PURLIN
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
#12-14 X 1 1/4" (12" C.C.)
THERMAL SPACER
(NOT BY CHIEF)
(2) #12-14 X 1 1/4"' PER CLOSURE
PURLIN CLOSURE (GPC)
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
TOP VIEW
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
GABLE EXPANSION TRIM (GET)
1/4-14 X 7/8" (12" C.C.)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
* 1/4-14 X 1 1/4" SHOULDER (24" C.C.)
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
GABLE EXTENSION CHANNEL (GEC)
INSIDE CLOSURE **
EAVE STRUT
TRIM TYPE EGFA EFHP
PURLIN SIZE
L OR H SYSTEM
***
JAMB TRIM (JT)
1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
EXTENSION FLASHING (EFCP)
DRAFTING NOTES: ** Inside closure must be provided on buildings with liner insulation system. *** High profile trim soffited gable ext STC / MSC.
8
HIGH HIGH
10
EGFA = EXTENSION GABLE FLASHING EFHP = EXT. FLASHING HIGH PROFILE
WALL PANEL
PURLIN CLOSURE INSTALLATION