High Profile Trim

MVF-MVP Gable Ext Lead End w High Profile Trim-CS Soffit and Thermal Spacer

1

PURLIN

* NOTE: THIS FASTENER MUST NOT HIT THE PURLIN.

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

GABLE EXTENSION DIMENSION

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

* 1/4-14 X 7/8" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR

PANEL CLIP w/FASTENERS

GABLE TRIM (GTVH)

PURLIN

(2) #12-14 X 1 1/4" (WALL COLOR) PANEL CLIP

MVF/MVP ROOF PANEL PURLIN CLOSURE (GPC)

PURLIN

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

#12-14 X 1 1/4" (12" C.C.) EXTENSION FLASHING (EFCP) #12-14 X 1" PANCAKE HEAD EACH PURLIN GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) (2) 1/4-14 X 7/8"

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

THERMAL SPACER

(NOT BY CHIEF)

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

TOP VIEW

GABLE EXPANSION TRIM (GET)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/4-14 X 7/8" (12" C.C.)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B)

**

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

EAVE STRUT

JAMB TRIM (JT)

INSIDE CLOSURE ***

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

CS SOFFIT PANEL

**

TRIM TYPE EFCP ECHP

PURLIN SIZE

L OR H SYSTEM

HIGH PROFILE TRIM-SOFFITED GABLE EXT MVF/MVP

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)

*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

8

HIGH HIGH

10

PURLIN CLOSURE INSTALLATION

WALL PANEL

EFCP = EXTENSION FLASHING HIGH PROFILE ECHP = EXT. FLASHING HIGH PROFILE

Made with FlippingBook flipbook maker