GENERAL INFORMATION
RECOMMENDED ERECTION PRACTICES (CONTINUED) ADJUSTING PANEL WIDTH NOTE Do not adjust panel coverage width more than 1/4" per panel. SHRINK : To shrink panel coverage, install a clip at the panel endlap or ridge with the base angled toward the panel. As the fastener is installed through the base of the clip and into the purlin, the clip base will rotate down to the purlin causing the top of the clip to move inward, shrinking panel coverage. Install the remainder of the clips as usual.
CAUTION: Shrinking can cause sever oil canning at low eave if transferred down to eave strut.
CLIP PLACEMENTS Keep clips located toward the interior side when clipping panel at exterior edges. I.e., high side eaves, Etc. This will keep the clip from fouling trims and closures
INTERIOR SIDE
EXTERIOR SIDE