MVF / MVP - Erection Manual
MVF/MVP M echanically S eamed V ertical Leg F lat M echanically S eamed V ertical Leg P encil-rib
®
SPECIAL ERECTION TECHNIQUES
MID-SLOPE FIXED CONDITION LOW EAVE
FLOATING HIGH EAVE PLATE
Refer to erection drawing General Details for expansion joint installation instructions if required.
EQ. EQ.
HIGH SYSTEM
*1/4"-14 X 1 1/4" WT (4) PER PANEL (Maintain 1 1/2" minimum from face of special trim to panel screw.) (2)1/4"-14 X 7/8" WT
SEE ERECTION DRAWINGS SEE ERECTION DRAWINGS
"PIG-TAIL" TAPE MASTIC
MVF/MVP ROOF PANEL
TAPE MASTIC
GUTTER STRAP (GSM) (2'-8" C.C. AT PANEL HI-RIBS)
#12-14 X 1 1/4"
*
FLOATING LOW EAVE PLATE
GUTTER (EGM)
(2)1/4"-14 X 1 1/4" SHOULDER FASTENERS THROUGH CENTER OF EACH SLOT
1/4"-14 X 7/8" WT (6" C.C.)
DOUBLE BEAD TAPE MASTIC
1/4"-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) EAVE STRUT
TRIM CAP
LOW SYSTEM
NOTES 1. The special details for use when a panel run exceeds the thermal movement capabilities of the panel clip. 2. A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement at the eave and ridge. 3. The standard floating ridge condition must be used in conjunction with this special eave detail. 4. The floating eave plate must be used to allow for panel movement at the eave. 5. Sliding clips have a maximum movement of 1" in each direction. Thermal calculations must be preformed for each project to ensure that the thermal movement of the roof will not exceed the design of the clips and slot in the special eave plate.
MVF/MVP-58
Version 2.0
SUBJECT TO CHANGE WITHOUT NOTICE