MVF MVP Roof Panel
MVF-MVP Gable Tail End
L DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.)* DOUBLE BEAD TAPE MASTIC ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
GABLE TRIM (GTV)
1
RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PANEL CLIP w/FASTENERS REFER TO ROOF PANEL PLAN) (2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP)
BL
1" 1 3 4 "
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
****
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
*NOTE: This fastener must not hit the purlin.
**OUTSIDE CLOSURE
**NOTE: Field cut outside closure for higher roof pitches.
WALL PANEL
*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
****DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION