MVF MVP Roof Panel
Common details and conditions found in MVF/MVP roof system applications.
MVF/MVP Roof Panel Sections & Details
All details downloadable in .dwg and .pdf
Table of Contents
MVF-MVP Roof - Eave MVF-MVP Eave Isometric w Gutter MVF-MVP Eave Low Side Gutter
MVF-MVP Eave Low Side Gutter No Wall Panel MVF-MVP Eave Low Side Gutter Oversized MVF-MVP Eave Isometric w Eave Trim MVF-MVP Eave Low Side Eave Trim MVF-MVP Eave High Side Eave Trim Thermal Spacer
MVF-MVP Eave Isometric w Trim Cap MVF-MVP Eave Low Side Trim Cap Only MVF-MVP Roof - Gable - Short Clip MVF-MVP Gable Lead End MVF-MVP Gable Lead End w Cut Roof Panel MVF-MVP Gable Lead End w Cut Roof Panel and Special Gable Trim MVF-MVP Gable Tail End MVF-MVP Gable Tail End w Special Gable Trim MVF-MVP Roof - Gable - Tall Clip (w Thermal Spacer) MVF-MVP Gable Lead End and Thermal Spacer MVF-MVP Gable Lead End w Cut Roof Panel and Thermal Spacer MVF-MVP Gable Lead End w Cut Roof Panel - Special Gable Trim and Thermal Spacer MVF-MVP Gable Tail End and Thermal Spacer MVF-MVP Gable Tail End w Special Gable Trim and Thermal Spacer MVF-MVP Roof - Height Change - Short Clip MVF-MVP Gable Lead End Height Change MVF-MVP Gable Lead End Height Change w Cut Roof Panel MVF-MVP Inset Gable Lead End Height Change and Panel Below MVF-MVP Inset Gable Lead End Height Change w Cut Roof Panel and Panel Below MVF-MVP Gable Tail End Height Change w Cut Roof Panel MVF-MVP Inset Gable Tail End Height Change w Cut Roof Panel and Panel Below MVF-MVP Outset Gable Lead End Height Change and Panel Below MVF-MVP Outset Gable Lead End Height Change w Cut Roof Panel and Panel Below MVF-MVP Outset Gable Tail End Height Change w Cut Roof Panel and Panel Below MVF-MVP High Side Height Change w Cee Girt to Taller Building MVF-MVP High Side Height Change w Cee Girt to Taller Building and Panel Below MVF-MVP High Side Height Change w Zee Girt to Taller Building MVF-MVP High Side Height Change w Zee Girt to Taller Building and Panel Below MVF-MVP Roof - Height Change - Tall Clip (w Thermal Spacer) MVF-MVP Gable Lead End Height Change-Thermal Spacer MVF-MVP Gable Lead End Height Change w Cut Roof Panel-Thermal Spacer MVF-MVP Inset Gable Lead End Height Change and Panel Below-Thermal Spacer
Table of Contents
MVF-MVP Inset Gable Lead End Height Change w Cut Roof Panel and Panel Below-Thermal Spacer MVF-MVP Gable Tail End Height Change w Cut Roof Panel-Thermal Spacer MVF-MVP Inset Gable Tail End Height Change w Cut Roof Panel and Panel Below-Thermal Spacer MVF-MVP Outset Gable Lead End Height Change and Panel Below-Thermal Spacer MVF-MVP Outset Gable Lead End Height Change w Cut Roof Panel and Panel Below-Thermal Spacer MVF-MVP Outset Gable Tail End Height Change w Cut Roof Panel and Panel Below-Thermal Spacer
MVF-MVP Roof - Existing Building - Short Clip MVF-MVP Gable Lead End to Taller Existing Building MVF-MVP Gable Tail End w Cut Roof Panel to Taller Existing Building MVF-MVP High Side Height Change to Taller Existing Building
MVF-MVP Roof - Existing Building - Tall Clip (w Thermal Spacer) MVF-MVP Gable Lead End and Thermal Spacers to Taller Existing Building MVF-MVP Gable Tail End w Cut Roof Panel and Thermal Spacers to Taller Existing Building MVF-MVP High Side Height Change w Thermal Spacers to Taller Existing Building MVF-MVP Roof - Roof Panel Splice SCREW_219.MVF-MVP Splice
MVF-MVP Roof - Eave
MVF-MVP Roof Eave
MVF-MVP Eave Isometric w Gutter
MVF/MVP ROOF PANEL
(22) 1/8" X 3/8" BLIND RIVETS
(4) 1/8" X 3/8" BLIND RIVETS
GABLE TRIM (GTVC)
GABLE TRIM (GTVC)
GUTTER STRAP (GSM) (FASTENERS NOT SHOWN)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
GABLE TRIM PLUG (TPLVC/TPRVC)
EAVE GUTTER (EGM)
(13) 1/8" X 3/8" BLIND RIVETS
FILL HOLE W/ 1/8" X 3/8" BLIND RIVET (BOTH LEGS)
GABLE CORNER TRIM (GCTVC)
GABLE EXPANSION TRIM (GET)
NOTE: 1. Use 2" lap at splices, and field cut 3/8" lockform at splice. 2. Fasten splice with (13) 1/8" x 3/8" blind rivets. 3. Use SIKA-511 sealant at splice.
NOTE: 1. Start gable trim 3" out from end of roof panel. Notch gable trim to avoid corner box rivets. 2. Start eave gutter 3" out from endwall building line. 3. Locate Gable Trim Plug as close to building line as possible. Field notch as required. 4. Use SIKA-511 sealant at plug and corner trim to gutter.
GABLE TRIM SPLICE
GABLE CORNER TRIM WITH GUTTER
MVF-MVP Eave Low Side Gutter
1/4-14 X 1 1/4" WT (4 PER PANEL)
MVF/MVP ROOF PANEL (2) 1/4-14 X 7/8" WT GUTTER STRAP (GSM) (2'-8" C.C. AT PANEL HI-RIBS)
BL
1/4-14 X 7/8" WT (6" C.C.)
2 "
4 1
TAPE MASTIC
#12-14 X 1 1/4" (TRIM COLOR)
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
1/4-14 X 7/8" (12" C.C.) TRIM CAP (TCM) EAVE GUTTER (EGM)
DOUBLE BEAD TAPE MASTIC
#12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
INSIDE CLOSURE *
WALL PANEL EAVE STRUT
DRAFTING NOTE: * Inside closure must be provided on buildings with liner insulation system.
MVF-MVP Eave Low Side Gutter No Wall Panel
1/4-14 X 1 1/4" WT (4 PER PANEL)
MVF/MVP ROOF PANEL (2) 1/4-14 X 7/8" WT GUTTER STRAP (GSM) (2'-8" C.C. AT PANEL HI-RIBS)
BL
1/4-14 X 7/8" WT (6" C.C.)
4 1
2 "
TAPE MASTIC
#12-14 X 1 1/4" (TRIM COLOR)
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
EAVE GUTTER (EGM)
DOUBLE BEAD TAPE MASTIC
EAVE STRUT
SPECIAL TRIM (SPT- ) *
#12-14 X 1 1/4" (12" C.C.)
DRAFTING NOTES: * Provide special tcm style trim cap. Trim cap to cover web depth.
MVF-MVP Eave Low Side Gutter Oversized
(2) 1/4-14 X 7/8" WT GUTTER STRAP (GSM) (2'-8" C.C. AT PANEL HI-RIBS) 1/4-14 X 1 1/4" WT (4 PER PANEL) MVF/MVP ROOF PANEL
1/4-14 X 7/8" WT (6" C.C.) (1/4-14 X 1 1/4" WT AT STRAP LOCATIONS)
BL
TAPE MASTIC
FLAT STRAP (PL- )
* 1/4-14 X 1" (EACH STRAP) #12-14 X 1 1/4" (TRIM COLOR)
4 1
2 "
SPECIAL EAVE GUTTER (SPT- )
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
1/4-14 X 7/8" (12" C.C.)
DOUBLE BEAD TAPE MASTIC
INSIDE CLOSURE
**
TRIM CAP (TCM)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C for AP PANEL)
WALL PANEL EAVE STRUT
DRAFTING NOTE: ** Inside closure must be provided on buildings with liner insulation system.
* Field drill 1/4" dia. hole in gutter strap, field drill 1/8" dia. Pilot hole in flat strap if required.
MVF-MVP Eave Isometric w Eave Trim
(22) 1/8" X 3/8" BLIND RIVETS
MVF/MVP ROOF PANEL
(4) 1/8" X 3/8" BLIND RIVETS
GABLE TRIM (GTVC)
GABLE TRIM (GTVC)
EAVE TRIM (ETM)
GABLE TRIM PLUG (TPLVC/TPRVC)
(13) 1/8" X 3/8" BLIND RIVETS
GABLE CORNER TRIM (GCTVC) FILL HOLE W/ 1/8" X 3/8" BLIND RIVET (BOTH LEGS)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
NOTE: 1. Start gable trim bottom leg 4" out from sidewall building line. Notch gable trim to avoid corner box rivets. 2. Start eave trim 3" out from endwall building line. 3. Locate Gable Trim Plug as close to building line as possible. Field notch as required. 4. Field cut roof panel at gable corner trim. (as required) 5. Use SIKA-511 sealant at plug and gable corner trim to eave trim. GABLE CORNER TRIM WITH EAVE TRIM
GABLE EXPANSION TRIM (GET)
NOTE: 1. Use 2" lap at splices, and field cut 3/8" lockform at splice. 2. Fasten splice with (13) 1/8" x 3/8" blind rivets. 3. Use SIKA-511 sealant at splice.
GABLE TRIM SPLICE
MVF-MVP Eave Low Side Eave Trim
PANEL OVERHANG PITCH 0:12 to 2 3/8:12 >2 3/8:12 to 4:12 ALL DIMENSIONS IN INCHES 6 1/2 7 1/2
1/4-14 X 1 1/4" WT (4 PER PANEL)
BL
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
1/4-14 X 7/8" WT (12" C.C.)
MVF/MVP ROOF PANEL
TAPE MASTIC
EAVE TRIM (ETM)
1/4-14 X 7/8" (12" C.C.) TRIM CAP (TCM)
DOUBLE BEAD TAPE MASTIC
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
INSIDE CLOSURE *
EAVE STRUT WALL PANEL 1/4-14 X 7/8" (12" C.C.)
OUTSIDE CLOSURE
DRAFTING NOTE: * Inside closure must be provided on buildings with liner insulation system.
MVF-MVP Eave High Side Eave Trim Thermal Spacer
** DRAFTING NOTE: Inside closure must be provided on buildings with liner insulation system.
*1/4-14 X 7/8" WT
DOUBLE BEAD TAPE MASTIC
PANEL CLIP w/ FASTENERS (REFER TO ROOF PANELING PLAN)
BL
RIDGE CLOSURE
5"
THERMAL SPACER
(NOT BY CHIEF)
1/4-14 X 7/8" WT (7 PER PANEL)
MVF/MVP ROOF PANEL
DOUBLE BEAD TAPE MASTIC HI-SIDE EAVE TRIM (HSEVC)
1/4-14 X 7/8" (12" C.C.) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
INSIDE CLOSURE **
1/4-14 X 7/8" (12" C.C.) EAVE SHIM TRIM (HSST) EAVE STRUT WALL PANEL
OUTSIDE CLOSURE
* For screw spacing refer to High Side detail in the MVF/MVP Roof Panel Erection manual.
MVF-MVP Eave Isometric w Trim Cap
(15) 1/8" X 3/8" BLIND RIVETS (4) 1/8" X 3/8" BLIND RIVETS
MVF/MVP ROOF PANEL
GABLE TRIM (GTVC)
GABLE TRIM (GTVC)
TRIM CAP (TCM)
GABLE TRIM PLUG (TPLVC/TPRVC)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
FILL HOLE W/ 1/8" X 3/8" BLIND RIVET (BOTH LEGS)
(13) 1/8" X 3/8" BLIND RIVETS
GABLE CORNER TRIM (GCTVC)
GABLE EXPANSION TRIM (GET)
NOTE: 1. Use 2" lap at splices, and field cut 3/8" lockform at splice. 2. Fasten splice with (13) 1/8" x 3/8" blind rivets. 3. Use SIKA-511 sealant at splice.
NOTE: 1. Start gable trim even with end of roof panel. Notch gable trim to avoid corner box rivets. 3. Locate Gable Trim Plug as close to building line as possible. Field notch as required. 4. Use SIKA-511 sealant at plug and corner trim.
GABLE TRIM SPLICE
GABLE CORNER TRIM WITH TRIM CAP
MVF-MVP Eave Low Side Trim Cap Only
1/4-14 X 1 1/4" WT (4 PER PANEL)
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
BL
4 1
2 "
MVF/MVP ROOF PANEL
1/4-14 X 7/8" (12" C.C.) TRIM CAP (TCM)
DOUBLE BEAD TAPE MASTIC
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
INSIDE CLOSURE *
EAVE STRUT WALL PANEL
DRAFTING NOTE: * Inside closure must be provided on buildings with liner insulation system.
MVF-MVP Roof - Gable - Short Clip
MVF-MVP Roof Gable Short Clip
MVF-MVP Gable Lead End
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)* (2) #12-14 X 1 1/4" (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR PRE-GLUED THERMAL SPACER (NOT BY CHIEF) ****
PANEL CLIP GABLE TRIM (GTVC) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
INSIDE CLOSURE
***
(2) 1/4-14 X 7/8"
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) PURLIN
*NOTE: This fastener must not hit the purlin.
**OUTSIDE CLOSURE
**NOTE: Field cut outside closure for higher roof pitches.
WALL PANEL
*** DRAFTING NOTE: Inside closure must be provided on buildings with liner insulation system.
****DRAFTING NOTE: Thermal spacer to be used with no insulation.
MVF-MVP Gable Lead End w Cut Roof Panel
ROOF PANEL CUT BACK DIM.
L CLIP LOCATION FROM B DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)* DOUBLE BEAD TAPE MASTIC
GABLE TRIM (GTVC) (2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP)
BL
1 3 4 "
PANEL CLIP (2) #12-14 X 1 1/4"
RAKE ANGLE (A-20-B) MVF/MVP ROOF PANEL
1"
RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
****
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C) ** OUTSIDE CLOSURE WALL PANEL
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
*NOTE: This fastener must not hit the purlin.
**NOTE: Field cut outside closure for higher roof pitches.
*** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.
****DRAFTING NOTE: Thermal spacer to be used with no insulation.
MVF-MVP Gable Lead End w Cut Roof Panel and Special Gable Trim
SPECIAL TRIM (SPT-__) (2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP) PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
L ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B DOUBLE BEAD TAPE MASTIC 1/4-14 X1 1/4" WT (6" C.C.)* DOUBLE BEAD TAPE MASTIC
BL
RAKE ANGLE (A-20-B) MVF/MVP ROOF PANEL
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
****
(2) 1/4-14 X 7/8" INSIDE CLOSURE
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.) **OUTSIDE CLOSURE WALL PANEL
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
* NOTE: This fastener must not hit the purlin.
** NOTE: Field cut outside closure for higher roof pitches.
**** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.
***DRAFTING NOTE: Thermal spacer to be used with no insulation
MVF-MVP Gable Tail End
L DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)* DOUBLE BEAD TAPE MASTIC ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
GABLE TRIM (GTVC)
RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PANEL CLIP w/FASTENERS REFER TO ROOF PANEL PLAN) (2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP)
BL
1" 1 3 4 "
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
****
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
*NOTE: This fastener must not hit the purlin. **NOTE: Field cut outside closure for higher roof pitches. *** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System. ****DRAFTING NOTE: Thermal spacer to be used with no insulation.
**OUTSIDE CLOSURE
WALL PANEL
MVF-MVP Gable Tail End w Special Gable Trim
L DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)* DOUBLE BEAD TAPE MASTIC ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
GABLE TRIM (SPT-___ )
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) (2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
PURLIN MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
****
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
1/4-14 X 7/8" (12" C.C.)
**NOTE: Field cut outside closure for higher roof pitches. *NOTE: This fastener must not hit the purlin. *** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System. ****DRAFTING NOTE: Thermal spacer to be used with no insulation.
**OUTSIDE CLOSURE
WALL PANEL
MVF-MVP Roof - Gable - Tall Clip (w Thermal Spacer)
MVF-MVP Roof Gable Tall Clip (w Thermal Spacer)
MVF-MVP Gable Lead End and Thermal Spacer
GABLE TRIM (GTVC)
THERMAL SPACER MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)* (2) #12-14 X 1 1/4"
(2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
BL
PANEL CLIP
RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
(NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
**NOTE: Field cut outside closure for higher roof pitches. *NOTE: This fastener must not hit the purlin. *** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.
**OUTSIDE CLOSURE
WALL PANEL
MVF-MVP Gable Lead End w Cut Roof Panel and Thermal Spacer
GABLE TRIM (GTVC)
L DOUBLE BEAD TAPE MASTIC CLIP LOCATION FROM B ROOF PANEL CUT BACK 1/4-14 X 1 1/4" WT (6" C.C)* DOUBLE BEAD TAPE MASTIC
BL
(2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP) (2) #12-14 X 1 1/4" PANEL CLIP RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1" 1 3 4 "
RAKE ANGLE (A-20-B) MVF/MVP ROOF PANEL THERMAL SPACER
(NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.) **OUTSIDE CLOSURE WALL PANEL
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
**NOTE: Field cut outside closure for higher roof pitches. *NOTE: This fastener must not hit the purlin. *** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.
MVF-MVP Gable Lead End w Cut Roof Panel - Special Gable Trim and Thermal Spacer
L ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C)* DOUBLE BEAD TAPE MASTIC
(2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP)
BL
GABLE TRIM (SPT-___)
RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
RAKE ANGLE (A-20-B) MVF/MVP ROOF PANEL THERMAL SPACER
(NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C) **OUTSIDE CLOSURE WALL PANEL
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
*NOTE: This fastener must not hit the purlin. **NOTE: Field cut outside closure for higher roof pitches. *** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.
MVF-MVP Gable Tail End and Thermal Spacer
ROOF PANEL CUT BACK DIM.
(2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP)
CLIP LOCATION FROM B
L
GABLE TRIM (GTVC)
BL
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)* DOUBLE BEAD TAPE MASTIC
RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
1 3 4 "
THERMAL SPACER MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
1"
(NOT BY CHIEF)
INSIDE CLOSURE
***
(2) 1/4-14 X 7/8"
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
**NOTE: Field cut outside closure for higher roof pitches. *NOTE: This fastener must not hit the purlin. *** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.
**OUTSIDE CLOSURE
WALL PANEL
MVF-MVP Gable Tail End w Special Gable Trim and Thermal Spacer
L DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)* DOUBLE BEAD TAPE MASTIC ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
(2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP)
BL
GABLE TRIM (SPT-___ )
RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
THERMAL SPACER MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
(NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
**NOTE: Field cut outside closure for higher roof pitches. *NOTE: This fastener must not hit the purlin. *** DRAFTING NOTE: inside closure must be provided on buildings with Liner Insulation System.
**OUTSIDE CLOSURE
WALL PANEL
MVF-MVP Roof - Height Change - Short Clip
MVF-MVP Roof Height Change Short Clip
MVF-MVP Gable Lead End Height Change
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
BL
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
***
1
4 "
RAKE ANGLE (A-20-L)
(2) #12-14 X 1 1/4"
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
1"
PANEL CLIP
**NOTE: This fastener must not hit the purlin. ***DRAFTING NOTE: Thermal spacer to be used with no insulation.
PURLIN
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
MVF-MVP Gable Lead End Height Change w Cut Roof Panel
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
ROOF PANEL CUT BACK DIM.
CLIP LOCATION FROM B
L
BL
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
2 1 4 "
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
1 1 2 "
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
***
1
4 "
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
PANEL CLIP RAKE ANGLE (A-20-L)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) #12-14 X 1 1/4"
DOUBLE BEAD TAPE MASTIC
**NOTE: This fastener must not hit the purlin. ***DRAFTING NOTE: Thermal spacer to be used with no insulation.
PURLIN
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
MVF-MVP Inset Gable Lead End Height Change and Panel Below
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
CLOSURE CLIPS (GCC-1) (TYP.)
**NOTE: This fastener must not hit the purlin.
PURLIN CLOSURE (TYP.)
*WALL PANEL (TYP.) INSIDE CLOSURE #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
(2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
BL
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
PURLIN
***
1
(2) #12-14 X 1 1/4"' PER CLOSURE
4 "
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
TOP VIEW
PANEL CLIP
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
1"
(2) #12-14 X 1 1/4"
HEIGHT CHANGE RAFTER (2) #12-24 X 1 1/2" (36" C.C.)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN) 1/4-14 X 7/8" (12" C.C.) PANELING CAP TRIM (SCT)
RAKE ANGLE (A-20)
EAVE STRUT
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
***DRAFTING NOTE:Thermal spacer to be used with no insulation.
PURLIN CLOSURE INSTALLATION
MVF-MVP Inset Gable Lead End Height Change w Cut Roof Panel and Panel Below
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
L ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
CLOSURE CLIPS (GCC-1) (TYP.)
**NOTE: This fastener must not hit the purlin. *WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4" BL
PURLIN CLOSURE (TYP.)
TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
2 1 4 "
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1 1 2 "
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
PURLIN
RAKE ANGLE (A-20-L)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4"' PER CLOSURE
PURLIN
1
4 "
***
TOP VIEW
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
PANEL CLIP
DOUBLE BEAD TAPE MASTIC
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) #12-24 X 1 1/2" (36" C.C.) RAKE ANGLE (A-20) HEIGHT CHANGE RAFTER #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
(2) #12-14 X 1 1/4"
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
EAVE STRUT
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PANELING CAP TRIM (SCT) 1/4-14 X 7/8" (12" C.C.)
***DRAFTING NOTE: Thermal spacer to be used with no insulation.
PURLIN CLOSURE INSTALLATION
MVF-MVP Gable Tail End Height Change w Cut Roof Panel
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
BL
L
**NOTE: This fastener must not hit the purlin.
2 1 4 "
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
1 1 2 "
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
***
1
4 "
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
DOUBLE BEAD TAPE MASTIC
RAKE ANGLE (A-20-L)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
PURLIN
***DRAFTING NOTE: Thermal spacer to be used with no insulation.
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
MVF-MVP Inset Gable Tail End Height Change w Cut Roof Panel and Panel Below
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
L ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
*WALL PANEL (TYP.) INSIDE CLOSURE #12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
HEIGHT CHANGE TRIM NBOTTOM (GHVB HEIGHT CHANGE TRIM TOP (GHVT) (2) #12-14 x 1 1/4" (EACH CLIP) WALL COLOR
BL
2 1 4 "
1 1 2 "
DOUBLE BEAD TAPE MASTIC 1/4-14 x 1 1/4" WT (6" C.C.)** TAPE MASTIC
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4"' PER CLOSURE
PURLIN
1
4 "
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
TOP VIEW
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) #12-24 X 1 1/2" (36" C.C.) RAKE ANGLE (A-20) HEIGHT CHANGE RAFTER **NOTE: This fastener must not hit the purlin. #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
DOUBLE BEAD TAPE MASTIC
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
PANELING CAP TRIM (SCT) 1/4-14 x 7/8" (12" C.C.) PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
EAVE STRUT
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
***DRAFTING NOTE: Thermal spacer to be used with no insulation.
PURLIN CLOSURE INSTALLATION
MVF-MVP Outset Gable Lead End Height Change and Panel Below
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
PURLIN CLOSURE (TYP.)
*WALL PANEL (TYP.) INSIDE CLOSURE #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC
PURLIN
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
1
4 "
(2) #12-14 X 1 1/4"' PER CLOSURE
TOP VIEW
RAKE ANGLE (A-20-L)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) #12-14 X 1 1/4"
PANEL CLIP
**NOTE: This fastener must not hit the purlin.
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
HEIGHT CHANGE RAFTER
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
EAVE STRUT
RAKE ANGLE (A-20)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (GA) (2 EACH PURLIN)
***DRAFTING NOTE: Thermal spacer to be used with no insulation
PANELING CAP TRIM (SCT)
PURLIN CLOSURE INSTALLATION
MVF-MVP Outset Gable Lead End Height Change w Cut Roof Panel and Panel Below
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
L ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
**NOTE: This fastener must not hit the purlin.
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
BL
2 1 4 "
(2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
PURLIN
1 1 2 "
TAPE MASTIC
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** DOUBLE BEAD TAPE MASTIC
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
(2) #12-14 X 1 1/4"' PER CLOSURE
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
TOP VIEW
PURLIN
***
1
4 "
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
PANEL CLIP
(2) #12-14 X 1 1/4"
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
RAKE ANGLE (A-20) #12-14 X 1 1/4" (GA) (2 EACH PURLIN) 1/4-14 X 7/8" (12" C.C.)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
EAVE STRUT
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PANELING CAP TRIM (SCT) HEIGHT CHANGE RAFTER
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN) #12-14 X 1 1/4" (2 EACH PURLIN)(WALL COLOR)
***DRAFTING NOTE: Thermal spacer to be used with no insulation.
PURLIN CLOSURE INSTALLATION
MVF-MVP Outset Gable Tail End Height Change w Cut Roof Panel and Panel Below
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
L
TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
*WALL PANEL (TYP.) INSIDE CLOSURE #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
BL
2 1 4 "
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
PURLIN
1 1 2 "
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
(2) #12-14 X 1 1/4"' PER CLOSURE
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
PURLIN
1
4 "
TOP VIEW
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
HEIGHT CHANGE RAFTER 1/4-14 X 7/8" (12" C.C.) **NOTE: This fastener must not hit the purlin. PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
DOUBLE BEAD TAPE MASTIC
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
EAVE STRUT
RAKE ANGLE (A-20)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN) #12-14 X 1 1/4" (GA) (2 EACH PURLIN)
***DRAFTING NOTE:Thermal spacer to be used with no insulation
PANELING CAP TRIM (SCT)
PURLIN CLOSURE INSTALLATION
MVF-MVP High Side Height Change w Cee Girt to Taller Building
INSIDE CLOSURE GIRT WALL PANEL
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL * For screw spacing refer to High Side Height Change detail in the MVF/MVP Roof Panel Erection manual.
RIDGE CLOSURE *1/4-14 X 7/8" WT EXPANSION TRIM (LHET) DOUBLE BEAD TAPE MASTIC PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) PRE-GLUED THERMAL SPACER (NOT BY CHIEF) *
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
4 "
MVF/MVP ROOF PANEL
3"
PURLIN DOUBLE BEAD TAPE MASTIC
*DRAFTING NOTE: Thermal spacer to be used with no insulation.
1/4-14 X 7/8" WT (7 PER PANEL)
MVF-MVP High Side Height Change w Cee Girt to Taller Building and Panel Below
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) WALL PANEL (TYP.)
* For screw spacing refer to High Side Height Change detail in the MVF/MVP Roof Panel Erection manual.
INSIDE CLOSURE
BL
RIDGE CLOSURE *1/4-14 X 7/8" WT EXPANSION TRIM (LHET) DOUBLE BEAD TAPE MASTIC PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
4 "
**
(2) #12-14 X 1 1/4" (GA) (36" C.C.)
3"
MVF/MVP ROOF PANEL
GIRT
PURLIN DOUBLE BEAD TAPE MASTIC
**DRAFTING NOTE: Thermal spacer to be used with no insulation.
1/4-14 X 7/8" WT (7 PER PANEL)
MVF-MVP High Side Height Change w Zee Girt to Taller Building
INSIDE CLOSURE GIRT WALL PANEL
* For screw spacing refer to High Side Height Change detail in the MVF/MVP Roof Panel Erection manual.
*1/4-14 X 7/8" WT EXPANSION TRIM (LHET) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
DOUBLE BEAD TAPE MASTIC
RIDGE CLOSURE
MVF/MVP ROOF PANEL PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
1
4 "
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
**
3"
PURLIN DOUBLE BEAD TAPE MASTIC
**DRAFTING NOTE: Thermal spacer to be used with no insulation.
1/4-14 X 7/8" WT (7 PER PANEL)
MVF-MVP High Side Height Change w Zee Girt to Taller Building and Panel Below
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C for AP PANEL) RAKE ANGLE (A-20-B) WALL PANEL (TYP.)
* For screw spacing refer to High Side Height Change detail in the MVF/MVP Roof Panel Erection manual.
INSIDE CLOSURE
BL
*1/4-14 X 7/8" WT EXPANSION TRIM (LHET)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
DOUBLE BEAD TAPE MASTIC
RIDGE CLOSURE
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) PRE-GLUED THERMAL SPACER (NOT BY CHIEF) **
1
4 "
(2) #12-14 X 1 1/4" (GA) (36" C.C.) GIRT
3"
MVF/MVP ROOF PANEL
**DRAFTING NOTE: Thermal spacer to be used with no insulation.
PURLIN DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (7 PER PANEL)
MVF-MVP Roof - Height Change - Tall Clip (w Thermal Spacer)
MVF-MVP Roof Height Change Tall Clip (w Thermal Spacer)
MVF-MVP Gable Lead End Height Change-Thermal Spacer
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
HEIGHT CHANGE TRIM TOP (GHVT)
**NOTE: This fastener must not hit the purlin.
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
BL
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1
4 "
THERMAL SPACER
(NOT BY CHIEF)
PANEL CLIP RAKE ANGLE (A-20-L) #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
(2) #12-14 X 1 1/4"
1"
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
PURLIN
MVF-MVP Gable Lead End Height Change w Cut Roof Panel-Thermal Spacer
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
**NOTE: This fastener must not hit the purlin.
L
TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
BL
2 1 4 "
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4
1 1 2 "
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
(6" C.C.for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
1
4 "
THERMAL SPACER
(NOT BY CHIEF)
PANEL CLIP
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
DOUBLE BEAD TAPE MASTIC
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
PURLIN
(2) #12-14 X 1 1/4"
MVF-MVP Inset Gable Lead End Height Change and Panel Below-Thermal Spacer
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
BL
(2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
THERMAL SPACER PURLIN
(NOT BY CHIEF)
1
4 "
(2) #12-14 X 1 1/4"' PER CLOSURE
TOP VIEW
PANEL CLIP
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
1"
(2) #12-14 X 1 1/4"
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
HEIGHT CHANGE RAFTER
PURLIN CLOSURE (GPC--) (PURLIN CLOSURE CLIPS NOT SHOWN)
(2) #12-24 X 1 1/2" (36" C.C.)
EAVE STRUT
PANELING CAP TRIM (SCT) 1/4-14 X 7/8" (12" C.C.)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
RAKE ANGLE (A-20)
**NOTE: This fastener must not hit the purlin. * Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN CLOSURE INSTALLATION
MVF-MVP Inset Gable Lead End Height Change w Cut Roof Panel and Panel Below-Thermal Spacer
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
L
CLOSURE CLIPS (GCC-1) (TYP.)
TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
BL
PURLIN CLOSURE (TYP.)
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4
2 1 4 "
1 1 2 "
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4"' PER CLOSURE
THERMAL SPACER
(NOT BY CHIEF)
TOP VIEW
1
4 "
DOUBLE BEAD TAPE MASTIC
PANEL CLIP
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
HEIGHT CHANGE RAFTER (2) #12-24 X 1 1/2" (36" C.C.) #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
(2) #12-14 X 1 1/4"
PURLIN
EAVE STRUT
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
1/4-14 X 7/8" (12" C.C.) PANELING CAP TRIM (SCT)
RAKE ANGLE (A-20)
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN CLOSURE INSTALLATION
**NOTE: This fastener must not hit the purlin.
MVF-MVP Gable Tail End Height Change w Cut Roof Panel-Thermal Spacer
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
**NOTE: This fastener must not hit the purlin.
L
BL
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
2 1 4 "
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
1 1 2 "
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
1
4 "
(NOT BY CHIEF)
THERMAL SPACER
RAKE ANGLE (A-20-L)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
DOUBLE BEAD TAPE MASTIC
PURLIN
MVF-MVP Inset Gable Tail End Height Change w Cut Roof Panel and Panel Below-Thermal Spacer
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
L
CLOSURE CLIPS (GCC-1) (TYP.)
BL
TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
PURLIN CLOSURE (TYP.)
2 1 4 "
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
1 1 2 "
1/4-14 X 1 1/4" WT (6" C.C.)** RAKE ANGLE (A-20-B) DOUBLE BEAD TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
(2) #12-14 X 1 1/4"' PER CLOSURE
MVF/MVP ROOF PANEL
(NOT BY CHIEF)
THERMAL SPACER
TOP VIEW
1
4 "
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
DOUBLE BEAD TAPE MASTIC
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
#12-14 1 1/4" (2 EACH PURLIN) (WALL COLOR)
HEIGHT CHANGE RAFTER
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
EAVE STRUT
(2) #12-24 X 1 1/2" (36" C.C.)
1/4-14 X 7/8" (12" C.C.) PANELING CAP TRIM (SCT)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
RAKE ANGLE (A-20)
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN CLOSURE INSTALLATION
**NOTE: This fastener must not hit the purlin.
MVF-MVP Outset Gable Lead End Height Change and Panel Below-Thermal Spacer
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN CLOSURE (TYP.)
**NOTE: This fastener must not hit the purlin.
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
BL
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"
PURLIN
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
(2) #12-14 X 1 1/4"' PER CLOSURE
TOP VIEW
1
4 "
THERMAL SPACER
(NOT BY CHIEF)
PANEL CLIP
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
1"
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
#12-14 X 1 1/4" (GA) (2 EACH PURLIN)
(2) #12-14 X 1 1/4"
EAVE STRUT
RAKE ANGLE (A-20)
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
HEIGHT CHANGE RAFTER
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PANELING CAP TRIM (SCT) 1/4-14 X 7/8" (12" C.C.)
PURLIN CLOSURE INSTALLATION