MVF MVP Roof Panel

MVF-MVP Gable Tail End w Special Gable Trim

L DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.)* DOUBLE BEAD TAPE MASTIC ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B

GABLE TRIM (SPT-___ )

1

PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) (2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

PURLIN MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)

****

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

INSIDE CLOSURE

***

PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)

(2) 1/4-14 X 7/8"

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET)

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

1/4-14 X 7/8" (12" C.C.)

**NOTE: Field cut outside closure for higher roof pitches. *NOTE: This fastener must not hit the purlin.

**OUTSIDE CLOSURE

****DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION

WALL PANEL