MVF MVP Roof Panel
MVF-MVP Gable Lead End w Cut Roof Panel and Thermal Spacer
GABLE TRIM (GTVC)
L DOUBLE BEAD TAPE MASTIC CLIP LOCATION FROM B ROOF PANEL CUT BACK 1/4-14 X 1 1/4" WT (6" C.C)* DOUBLE BEAD TAPE MASTIC
BL
(2) #12-14 X 1 1/4" WALL COLOR (EACH CLIP) (2) #12-14 X 1 1/4" PANEL CLIP RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1" 1 3 4 "
RAKE ANGLE (A-20-B) MVF/MVP ROOF PANEL THERMAL SPACER
(NOT BY CHIEF)
INSIDE CLOSURE
***
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.) **OUTSIDE CLOSURE WALL PANEL
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
**NOTE: Field cut outside closure for higher roof pitches. *NOTE: This fastener must not hit the purlin. *** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.
Made with FlippingBook - Online catalogs