MVF MVP Roof Panel
MVF-MVP Gable Lead End Height Change w Cut Roof Panel-Thermal Spacer
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
**NOTE: This fastener must not hit the purlin.
L
TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
BL
2 1 4 "
*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4
1 1 2 "
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
(6" C.C.for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
1
4 "
THERMAL SPACER
(NOT BY CHIEF)
PANEL CLIP
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
DOUBLE BEAD TAPE MASTIC
PANEL CLIP w/FASTENERS (REFER TO ROOF PANELING PLAN)
PURLIN
(2) #12-14 X 1 1/4"