ERECTION SEQUENCE
STEP 13
6
3 2 5
4
1
LAST PANEL RUN After installing the rake support along the steel line, lay the last insulation run. Lay the last panel run. Temporarily fasten the male leg to the rake support with locking pliers.
RAKE SUPPORT
Refer to Erection Drawings Details for Gable Detail to determine how your roof should end.
MINIMUM 1"
If the panel ends 2" - 4" away from the rake support due to an out-of-square condition or other factors, simply install the panel clips. This system allows for the roof to be trimmed in the high.
RAKE TRIM
VARIABLE TERMINATION TRIM
CAUTION The roof should be swept clean of any drill shavings at the end of the day to prevent rust.
SUBJECT TO CHANGE WITHOUT NOTICE