SPECIAL ERECTION TECHNIQUES VENTED RIDGE w/Vent Material
1/4"-14 X 7/8" WT FASTENERS
RIDGE FLASHING
4"
1/4"-14 X 7/8" WT (6" C.C.)
12"
8"
METAL VENT
TRI-BEAD TAPE MASTIC
PRE-CUT TRI-BEAD TAPE MASTIC
VENT MATERIAL
RIDGE CLOSURE
STC PANEL
BACK-UP PLATE
1/4"-14 X 1 1/4" WT (9) PER PANEL
INSULATION
(2) CLIP FASTENERS (SEE ROOF PANELING PLAN) PURLIN
CUT LINE
6"
CAULK ON THE INSIDE WITH SIKA-201
VENT MATERIAL
1½"
1½"
1½"
1½"
5 ¼"
24" Panels = 4 SPACES AT 5 ¼" 18" Panels = 3 SPACES AT 5"
OUTSIDE CLOSURE
1/4"-14 X 7/8" WT
NOTE: Extend metal vent material 6" past the gable trim. Field slit and bend back to fill area between vertical face of vent and the ridge flashing plug. Caulk where endcap is formed with SIKA-201.