STC - Erection Manual
STC S nap T ight C onstruction
®
SPECIAL ERECTION TECHNIQUES MID-SLOPE FIXED CONDITION LOW EAVE
FLOATING HIGH EAVE PLATE
Refer to erection drawing General Details for expansion joint installation instructions if required.
1/4"-14 X 1 1/4" WT (8) PER PANEL
2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS
HIGH SYSTEM
SEE ERECTION DRAWINGS
(2)1/4"-14 X 7/8" WT
TRI-BEAD TAPE MASTIC
SEE ERECTION DRAWINGS
2" STRIP OF TRI-BEAD TAPE MASTIC UNDER EACH FASTENER
DOUBLE BEAD TAPE MASTIC
TRAP RIB PLUG (TRP)
INSIDE CLOSURE
DOUBLE BEAD TAPE MASTIC GUTTER STRAP (GSM)
STC PANEL
#12-14 X 1 1/4"
FLOATING LOW EAVE PLATE
(2)1/4"-14 X 1 1/4" SHOULDER FASTENERS THROUGH CENTER OF EACH SLOT
1/4"-14 X 1 1/4" (2 EACH CLOSURE) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) EAVE STRUT TRI-BEAD TAPE MASTIC
GUTTER (EGM) 1/4"-14 X 7/8" WT (6" C.C.)
1/4-14 X 7/8" (12" C.C.)
TRIM CAP
LOW SYSTEM
NOTES 1. The special details for use when a panel run exceeds the thermal movement capabilities of the panel clip. 2. A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement at the eave and ridge. 3. The standard floating ridge condition must be used in conjunction with this special eave detail. 4. The floating eave plate must be used to allow for panel movement at the eave. 5. Sliding clips have a maximum movement of 1" in each direction. Thermal calculations must be preformed for each project to ensure that the thermal movement of the roof will not exceed the design of the clips and slot in the special eave plate.
STC-62
Version 7.1
SUBJECT TO CHANGE WITHOUT NOTICE