STC MSC Roof Panel

MSC 2-Inch-Gable Lead End-Taller Existing Building-Thermal Spacer

COUNTER FLASHING (NOT BY CHIEF)

1

CAULKING (NOT BY CHIEF) SPECIAL TRIM (SPT- ) TRI-BEAD TAPE SEALER

L EXIST. B

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- )(BEFORE ASSEMBLING) (SEE INSET DETAIL)

FASTENER AT 12" C.C. (NOT BY CHIEF)

1/4-14 X 1 1/4" WT (12" C.C.)

RAKE SUPPORT (A-20-2)

THERMAL SPACER MSC ROOF PANEL

(NOT BY CHIEF)

HEIGHT CHANGE TRIM BOTTOM (GHMBF) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

PURLIN

3"

1/4-14 X 1 1/4" SHOULDER (24" C.C.)* RAKE ANGLE (A-20-B)

* IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT AND THAT THESE FASTENER MUST NOT HIT THE PURLINS.

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)