STC MSC Roof Panel
MSC 2-Inch-Gable End-Field Bend Vertical Leg-Taller Existing Building
1
COUNTER FLASHING (NOT BY CHIEF)
CAULKING (NOT BY CHIEF) SPECIAL TRIM TOP (SPT- ) TRI-BEAD TAPE SEALER
L EXIST. B
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING) (SEE INSET DETAIL)
FASTENER AT 12" C.C. (NOT BY CHIEF)
1/4-14 X 1 1/4" WT (12" C.C.)
RAKE SUPPORT (A-20-2)
(NOT BY CHIEF) * PRE-GLUED THERMAL SPACER
MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
* DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.
HEIGHT CHANGE TRIM BOTTOM (GHMBF) ** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT AND THAT THESE FASTENERS MUST NOT HIT THE PURLINS.
3"
PURLIN
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)
RAKE ANGLE (A-20-B) 1/4-14 X 1 1/4" SHOULDER (24" C.C.)**