STC MSC Roof Panel
MSC 2-Inch-Gable End-Field Bend Vertical Leg-Taller Existing Building-Thermal Spacer
COUNTER FLASHING (NOT BY CHIEF)
TRI-BEAD TAPE SEALER SPECIAL TRIM TOP (SPT- ) CAULKING (NOT BY CHIEF)
1
L EXIST. B
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- )(BEFORE ASSEMBLING) (SEE INSET DETAIL)
FASTENER AT 12" C.C. (NOT BY CHIEF)
1/4-14 X 1 1/4" WT (12" C.C.)
RAKE SUPPORT (A-20-2)
MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION) THERMAL SPACER (NOT BY CHIEF)
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
* IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT AND THAT THESE FASTENERS MUST NOT HIT THE PURLINS.
PURLIN #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) 1/4-14 X 1 1/4" SHOULDER (24" C.C.)* RAKE ANGLE (A-20-B)
3"
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- )(BEFORE ASSEMBLING)