STC MSC Roof Panel

STC-MSC Gable Tail End

GABLE TRIM (GTM) RAKE SUPPORT (A-20-S) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) STC/MSC ROOF PANEL

1

BL

****

THERMAL SPACER (NOT BY CHIEF)

INSIDE CLOSURE

***

**** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.

(2) 1/4-14 X 7/8"

GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) 1/4-14 X 7/8" (12" C.C.) WALL PANEL **OUTSIDE CLOSURE

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN

* It is important that 1/4-14 X 1 1/4" SHOULDERS are installed through the center of the slotted holes of the rake support. ** NOTE: Field cut outside closure for higher roof pitches. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.