Special Features

Canopy Boxed-In MSC-STC Roof Eave Gutter w FSP Soffit

NOTES: * Field cut (2) 2" long strips of tri-bead tape mastic & center under 1/4-14 x 7/8" WT's between gutter strap and roof panel. ** See Isometric Trapezoid Plug Installation detail for installation instructions. *** For screw spacing refer to High Side Height Change detail in the MSC/STC Roof Panel Erection Manual. **** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll. ***** Provide air gap of 1/4" min. at bottom of panel to avoid corrosion. ****** Purlin is a typical example. See Canopy framing drawings for required number of purlin rows.

BL

X'-X"

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) HEIGHT CHANGE ANGLE (A-20-B) WALL PANEL (TYP.)

TRI-BEAD TAPE MASTIC ***1/4-14 X 7/8" WT HEIGHT CHANGE TRIM (LHET) INSIDE CLOSURE

*(2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS 1/4-14 X 1 1/4" WT PANEL TO EAVE (8 PER PANEL)

(2) #12-14 X 1 1/4" (GA) ( 36" C.C.)

***** 1

****TRI-BEAD TAPE MASTIC OUTSIDE CLOSURE 1/4-14 X 1 1/4" WT (9 PER PANEL) PRE-TAPED THERMAL SPACER PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)

4 "

**TRAPEZOID PLUG (TRP) EACH HIGH RIB TRI-BEAD TAPE MASTIC (TOP AND BOTTOM)

4 1

2 "

HEIGHT CHANGE GIRT

DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM) GUTTER STRAP (GSM) AT EACH PANEL HI-RIB

STC/MSC CANOPY ROOF PANEL

4"

8"

#12-14 X 1 1/4" (TRIM COLOR)

METAL INSIDE CLOSURE

****** CANOPY ROOF PURLIN

1/4-14 X 1" (2) PER CLOSURE

EAVE GUTTER (EGM) 1/4-14 X 7/8" WT (6" C.C.)

TRIM CAP (TCM)

EAVE STRUT

CANOPY FASCIA PANEL CEE SOFFIT PURLIN #12-14 X 1 1/4" (TYP.) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

HEADER #12-14 X 1 1/4" (12" C.C.) (TYP.)

XXX'-X"

***** 1

4 "

XXX'-X"

****** SOFFIT PURLIN

SOFFIT PANELING CAP TRIM (SSCT) JAMB TRIM(JT) 1/8" X 3/8" BLIND RIVETS (12" C.C.)

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

SOFFIT TRIM (VPST)

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)

1/8" X 3/8" BLIND RIVETS (12" C.C.)

FSP SOFFIT PANEL

DRAFTING NOTE: ยท 26 GA FSP soffit must always have 1/4-14 x 7/8" fasteners located at ribs at end supports. Change fasteners to "DIM" layer.