Special Features
Canopy Boxed-In MSC-STC Roof at Gable Lead End FSP Soffit
NOTES: * It is important that 1/4-14 X 1 1/4" SHOULDERS are installed through the center of the slotted holes of the rake support. ** Field cut outside closure for higher roof pitches. ***Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
CL
X'-X"
1/4-14 X 1 1/4" WT (12" C.C.) TRI-BEAD TAPE SEALER *1/4-14 X 1 1/4" SHOULDER (24" C.C.) STC/MSC ROOF PANEL PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
RAKE ANGLE (A-20-B) RAKE SUPPORT (A-20-S) GABLE TRIM (GTMC)
PURLIN
1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) (2) 1/4-14 X 7/8"
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
**OUTSIDE CLOSURE
CANOPY FASCIA PANEL
#12-14 X 1 1/4" (TYP.) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
CANOPY END PURLIN SUPPORT (A-20)
#12-14 X 1" PANCAKE HEAD (12"C.C.)
XXX'-X"
1
4 "
XXX'-X"
SOFFIT TRIM (VPST) 1/8" X 3/8" BLIND RIVETS (12" C.C.)
FSP SOFFIT PANEL
SOFFIT PANELING SUPPORT (SSSP)