Special Features

Parapet at Low Side w CS - Multi-gutter

* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION

1

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4 -14 X 1 1/4" WT (6" C.C.) BACKUP PANEL 1/4 - 14 X 7/8" WT (12" C.C.) 1/4 -14 X 1 1/4" WT (6" C.C.) PARAPET GIRT OUTSIDE CLOSURE

#12-14 X 1 1/4" (24" C.C.)

BL

PARAPET CAP TRIM (PCT-X) * PARAPET CLEAT (PCC-X)

XXX'-X"

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

#12 - 14 X 1" PANCAKE HEAD (12"C.C)

PARAPET/WALL PANEL

INSIDE CLOSURE W/ MASTIC TOP & BOTTOM

XXX'-X"

GIRT #12-14 X 1 1/4" (12" C.C.) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

1/4 - 14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL

** MULTI-GUTTER (MG-X) EAVE STRUT

** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps