Special Features
Parapet at Low Side with STC-MSC Roof Panel-Multi-gutter and Nichiha Panel Not by Chief
Tape mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
***
HORIZONTAL LEG OF PARAPET CAP TRIM
SPECIAL PARAPET CAP TRIM (SPT-X) #12-14 X 1 1/4" (24" C.C.) SPECIAL PARAPET CLEAT (SPT-X)
1/4-14 X 1 1/4" WT (6" C.C.) PARAPET GIRT
BL
X"
OUTSIDE CLOSURE
PANCAKE HEAD FASTENER (NOT BY CHIEF) (12" C.C.)
X
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4-14 X 1 1/4" WT (6" C.C.) BACKUP PANEL 1/4-14 X 7/8" WT (12" C.C.)
#12-14 X 1 1/4" (_" C.C.) * _" NICHIHA PANELS (NOT BY CHIEF) SPECIAL PURCHASED (IF BY CHIEF) XXX'-X"
1/4-14 X 1 1/4" WT PANEL TO EAVE (8 PER PANEL)
TRI-BEAD TAPE MASTIC
PARAPET/WALL PANEL
XXX'-X"
GIRT #12-14 X 1 1/4" (12" C.C.) *** MULTI-GUTTER (MG-X)
STC/MSC ROOF PANEL
TRI-BEAD TAPE MASTIC 1/4-14 X 1" (2) PER CLOSURE METAL INSIDE CLOSURE
NOTE: This run of multi-gutter uses (2) MGEC- as endcaps.
* Connection of nichiha panels (not by chief), to wall panel is not by Chief. ** Refer to the Multi-Gutter Endcap and Splice detail for installation.
EAVE STRUT
DRAFTING NOTES: *** Dimension horiz. leg of cap trim. Have pm verify dim. with bldr.