Special Features
Parapet at High Side with STC-MSC Roof Panel-Support Girt Thermal Spacer and Nichiha Panel Not by Chief
NOTE: ·
HORIZONTAL LEG OF PARAPET CAP TRIM
****
Field notch the hems 2" to allow for the trim to lap. · Leave a two inch space between the cleats at the connection of the parapet cap trim. · Apply a 1/4" bead of Sikalastomer-511 and install 10 blind rivets at each joint.
Tape mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
PARAPET GIRT
SPECIAL PARAPET CAP TRIM (SPT-X) 1/4-14 X 1 1/4" WT (6" C.C.) (TYP) OUTSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.)
BL
X"
X"
SPECIAL PARAPET CAP TRIM (SPT-X) (OVERLAPPING)
DRAFTING NOTE: **** Dimension horiz. leg of cap trim. Have pm verify dim. with bldr. *** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll. * Connection of nichiha panels (not by Chief), to wall panel is not by chief. ** For screw spacing refer to High Side Height Change detail in the MSC/STC Roof Panel Erection Manual.
#12-14 X 1 1/4" (24" C.C.)
BACKUP PANEL
SIKA-511
XXX'-X"
HEIGHT CHANGE GIRT INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM HEIGHT CHANGE TRIM (LHET) ** 1/4-14 X 7/8" WT
SPECIAL PARAPET CAP TRIM (SPT-X) (UNDER LAPPING)
SPECIAL PARAPET CLEAT (SPT-X)
2"
PANCAKE HEAD FASTENER (NOT BY CHIEF) (12" C.C.) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PARAPET/WALL PANEL SPECIAL PURCHASED (IF BY CHIEF)
2"
1"
TRI-BEAD TAPE MASTIC
1/4-14 X 1 1/4" WT (9 PER PANEL)
1
4 "
SPECIAL PARAPET CLEAT (SPT-X)
* _" NICHIHA PANEL (NOT BY CHIEF)
2" GAP
OUTSIDE CLOSURE TRI-BEAD TAPE MASTIC BACK-UP PLATE
STC/MSC ROOF PANEL THERMAL SPACER (NOT BY CHIEF) PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)
SPECIAL PARAPET CLEAT (SPT-X) ISOMETRIC PARAPET / FACADE CAP TRIM SPLICE DETAIL
4"
8"
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN