Special Features
Parapet at Endwall w STC-MSC Gable Lead End w Thermal Spacer
* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION. .
PARAPET CAP TRIM (PCT-X) 1/4-14 X 7/8" WT (12" C.C.) OUTSIDE CLOSURE
PARAPET GIRT
BL
#12-14 X 1 1/4" (24" C.C.) * PARAPET CLEAT (PCC-X)
**BACK-UP PANEL
HEIGHT CHANGE TRIM TOP (GHMTF) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
XXX'-X"
#12 - 14 X 1" PANCAKE HEAD (12"C.C)
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSERT DETAIL) TRI-BEAD TAPE SEALER
OUTSIDE CLOSURE
PARAPET/WALL PANEL #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
STC/MSC ROOF PANEL 1/4-14 X 1 1/2" WT (12" C.C.)
HEIGHT CHANGE ANGLE (A-20-H) 1/4-14 X 1 1/4" WT (6" C.C.) (TYP) RAKE SUPPORT (A-20-T)
THERMAL SPACER
(NOT BY CHIEF)
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
1
4 "
1 4 "
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
PURLIN
2"
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)
*** 1/4-14 X 1 1/4" SHOULDER (24" C.C.) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
*** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
Made with FlippingBook flipbook maker