Special Features

Parapet at Endwall w STC-MSC Gable Tail End w Thermal Spacer

* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION

** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PARAPET CAP TRIM (PCT-X) 1/4-14 X 7/8" WT (12" C.C.) OUTSIDE CLOSURE

PARAPET GIRT

BL

#12-14 X 1 1/4" (24" C.C.) * PARAPET CLEAT (PCC-X)

***BACK-UP PANEL

OUTSIDE CLOSURE

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

XXX'-X"

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER HEIGHT CHANGE TRIM TOP (GHMTF)

PARAPET/WALL PANEL #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) #12 - 14 X 1" PANCAKE HEAD (12"C.C)

STC/MSC ROOF PANEL

1

1/4-14 X 1 1/4" WT (12" C.C.) 1/4-14 X 1 1/4" WT(6" C.C.) (TYP)

4 "

THERMAL SPACER

(NOT BY CHIEF)

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

HEIGHT CHANGE ANGLE (A-20-H)

1 4 "

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

2"

RAKE SUPPORT (A-20-T)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

PURLIN

** 1/4-14 X 1 1/4" SHOULDER (24" C.C.)

*** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

Made with FlippingBook flipbook maker