Special Features

Parapet at Endwall w STC-MSC Gable End w Field Bend Vertical Leg and Thermal Spacer

PARAPET CAP TRIM (PCT-X) 1/4-14 X 7/8" WT (12" C.C.) OUTSIDE CLOSURE

** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

PARAPET GIRT

#12-14 X 1 1/4" (24" C.C.) * PARAPET CLEAT (PCC-X)

BL

**BACK-UP PANEL

OUTSIDE CLOSURE

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

XXX'-X"

STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION) 1/4-14 X 1 1/4" WT (12" C.C.) SIKA 511 CAULK IN LOCKFORM OF HEIGHT (CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER HEIGHT CHANGE TRIM TOP (GHMTF)

#12 - 14 X 1" PANCAKE HEAD (12"C.C)

* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION

PARAPET/WALL PANEL #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

RAKE SUPPORT (A-20-T) HEIGHT CHANGE ANGLE (A-20-H) 1/4-14 X 1 1/4" WT (6" C.C.) (TYP)

1

4 "

(NOT BY CHIEF)

THERMAL SPACER

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

1 4 "

PURLIN

HEIGHT CHANGE TRIM BOTTOM (GHMBF) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

2"

*** 1/4-14 X 1 1/4" SHOULDER (24" C.C.)

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

*** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.