Parapet at Endwall w STC-MSC Gable Lead End Thermal Spacer and Nichiha Panel NBC
** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT. * NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF. *** NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION **** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
HORIZONTAL LEG OF PARAPET CAP TRIM
BL
X"
#12-14 X 1 1/4" (24" C.C.)
SPECIAL PARAPET CAP TRIM (SPT-X)
*** SPECIAL PARAPET CLEAT (SPT-X)
X
1/4-14 X 7/8" WT (12" C.C.) 1/4-14 X 1 1/4" WT (6" C.C.) PARAPET GIRT
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
XXX'-X"
OUTSIDE CLOSURE ****BACK-UP PANEL
PANCAKE HEAD FASTENER (NOT BY CHIEF)(12" C.C.) SPECIAL PURCHASED (IF BY CHIEF)
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER
PARAPET/WALL PANEL
* _" NICHIHA PANEL (NOT BY CHIEF)
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL)
HEIGHT CHANGE ANGLE (A-20-H)
1/4-14 X 1 1/4" WT (12" C.C.)
1/4-14 X 1 1/4" WT (6" C.C.)
STC/MSC ROOF PANEL THERMAL SPACER
(NOT BY CHIEF)
1
4 "
1 4 "
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
2"
RAKE SUPPORT (A-20-T)
** 1/4-14 X 1 1/4" SHOULDER (24" C.C.)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
PURLIN
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)