Wall Panel and Trim

Animated publication

Wall Panel and Trim Sections & Details

All details downloadable in .dwg and .pdf

Table of Contents

Wall Panel Details AP Wall Details CS Wall Details AP Panel Openings AP Metal Bldg Walkdoor-KD-Others AP Metal Bldg Walkdoor-PA-SF AP OHD or 3-Sided Opening AP Window by Chief

AP Window or 4-Sided Opening w Jamb Trim–JT AP Window or 4-Sided Opening w Sill Flashing–WFS AP Window or 4-Sided Opening w Trim Only CS Panel Openings CS Metal Bldg Walkdoor-KD-Others CS Metal Bldg Walkdoor-PA-SF CS OHD or 3-Sided Opening CS Window by Chief CS Window or 4-Sided Opening w Jamb Trim–JT CS Window or 4-Sided Opening w Sill Flashing–WFS CS Window or 4-Sided Opening w Trim Only Wainscot - Lapped T19.Wainscot Lapped at Zee w A-20

T21.Wainscot Lapped HRC T22.Wainscot Lapped Zee Wainscot Lapped at Sill

Wainscot Lapped Mid-wall at Cee Wainscot Lapped Mid-wall at Zee Wainscot - No Lap (w WTT Trim)

T15.Wainscot No Lap WTT at Cee T17.Wainscot No Lap WTT at HRC T18.Wainscot No Lap WTT at Zee Wainscot No Lap WTT at Sill w Window by Chief

Wainscot No Lap WTT Mid-Wall at Cee Wainscot No Lap WTT Mid-Wall at Zee Base Conditions Base Trim NONE-Lap

Base Trim NONE-No Lap Base Trim NONE-Notch Base Trim Simple L BT-Lap Base Trim Simple L BT-No Lap Base Trim Simple L BT-Notch

Table of Contents

Base Trim w Drip Edge BTN-Lap Base Trim w Drip Edge BTN-No Lap Base Trim w Drip Edge BTN-Notch

Base Trim w Drip Edge Vertical BTNV-Lap Base Trim w Drip Edge Vertical BTNV-No Lap Base Trim w Drip Edge Vertical BTNV-Notch Base Trim w Return Leg BTM-Lap Base Trim w Return Leg BTM-No Lap Base Trim One Piece OPB Wallite Light Transmitting Panel

AP Wall AP Light Transmitting Panel w AP Liner Panel Horizontal Section AP Wall AP Light Transmitting Panel w CS Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w AP Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w CS Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w Full Height Liner CS Wall CS Light Transmitting Panel w AP Liner Panel Horizontal Section CS Wall CS Light Transmitting Panel w CS Liner Panel Horizontal Section CS Wall-CS Light Transmitting Panel or AP Wall-AP LTP w Full Height Liner

Wall Panel Details

Wall Panel Details

AP Wall Details

AP WALL PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.

12"

NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Insulation has not been shown for clarity. · Blanket insulation must be trimmed above the bottom of panel to prevent water from "WICKING" into the insulation. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · #12-14 X 1 1/4" Fastener spacing is (12" C.C.) unless otherwise noted. ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness ** #12-14 X 2", Blanket Insulation >4" thickness · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather.

Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")

STEEL LINE

BL

GIRT

Clip offset

RAKE ANGLE

WALL PANEL

TAPE MASTIC AT SIDELAPS, IF ORDERED ** #12-14 X 1 1/4 (12" C.C.)

**#12-14 X 1 1/4" (12" C.C.)

TOP OF PURLIN

NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.

**#12-14 X 1 1/4" (12" C.C.)

1"

BL

AP PANELING

Intermediate Girt Detail

STEEL LINE

Eave Height

BL

EAVE STRUT

WALL PANEL

BL

PANEL SIDELAP EAVE STRUT

Sidewall Eave Detail Low side shown. High Side Typical.

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

GIRT

12" (TYP.)

RISE

3" 3"

6"

MIN.

**#12-14 X 1 1/4" (12" C.C.)

WALL PANEL

BL

Panel Endlap Detail

* 1/4-14 X 7/8" (TYP.)

AP PANEL FASTENER INSTALLATION

AP PANEL AT GABLE END

1/4-14 X 7/8" (TYP.) (18" C.C.)

NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.

NOTES: ·

Field cut panel if required for corner trim.

· Corner Angle connection/fasteners, refer to Girt Corner Detail.

GIRT

12" (TYP.)

SHEETING SUPPORT (SSP)

1/4-14 X 7/8" (18" C.C.)

OPTIONAL TAPE MASTIC CENTERED ON HIGH RIB (REFER TO DRAWING COVER PAGE FOR WALL MASTIC REQUIREMENTS)

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

STEEL LINE

CORNER TRIM (CTA)

RETURN LEG

L

B

* 18" (TYP.)

CORNER ANGLE (A-20)

PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)

12" (TYP.)

AP PANEL 1/4-14 X 7/8" (12" C.C.) (TYP.)

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

2 1/2"

2 1/2"

1 1/2"

BASE MEMBER

TAPE MASTIC AT SIDELAPS, IF ORDERED

B

L

AP PANEL INSTALLATION

AP PANEL SIDE LAPS

AP PANEL STANDARD CORNER CONDITION

CS Wall Details

CS WALL PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.

6"

3"

NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Insulation has not been shown for clarity. · Blanket insulation must be trimmed above the bottom of panel to prevent water from "WICKING" into the insulation. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · #12-14 X 1 1/4" Fastener spacing is (12" C.C.) unless otherwise noted. ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness ** #12-14 X 2", Blanket Insulation >4" thickness · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather.

Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")

STEEL LINE

GIRT

Clip offset

WALL PANEL

RAKE ANGLE

TAPE MASTIC AT SIDELAPS, IF ORDERED ** #12-14 X 1 1/4 (6" C.C.)

**#12-14 X 1 1/4" (12" C.C.)

TOP OF PURLIN

NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.

**#12-14 X 1 1/4" (6" C.C.)

1"

BL

CS PANELING

Intermediate Girt Detail

STEEL LINE

Eave Height

EAVE STRUT

WALL PANEL

BL

PANEL SIDELAP EAVE STRUT

Sidewall Eave Detail Low side shown. High Side Typical.

GIRT

6" (TYP.)

3"

** #12-14 X 1 1/4" (6" C.C.) (TYP.)

RISE

3" 3"

6"

MIN.

**#12-14 X 1 1/4" (6" C.C.)

WALL PANEL

BL

1/4-14 X 7/8" (TYP.) (18" C.C.)

Panel Endlap Detail

* 1/4-14 X 7/8" (TYP.)

CS PANEL FASTENER INSTALLATION

CS PANEL AT GABLE END

NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.

NOTES: ·

Field cut panel if required for corner trim.

· Corner Angle connection/fasteners, refer to Girt Corner Detail. · Connection of panel to structure at corner is by the corner trim fasteners.

GIRT

12" (TYP.)

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

1/4-14 X 7/8" (18" C.C.)

CORNER TRIM (CT)

STEEL LINE

CORNER ANGLE (A-20)

RETURN LEG

PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)

OPTIONAL TAPE MASTIC CENTERED ON HIGH RIB (REFER TO DRAWING COVER PAGE FOR WALL MASTIC REQUIREMENTS)

* 18" (TYP.)

L

B

6" (TYP.)

3"

CS PANEL

* 1/4-14 X 7/8" (TYP.)

** #12-14 X 1 1/4" (6" C.C.) (TYP.)

2 1/2"

1 1/2"

#12-14 X 1 1/4 (12" C.C.) (TYP.)

BASE MEMBER

B

L

CS PANEL INSTALLATION

CS PANEL SIDE LAPS

CS PANEL STANDARD CORNER CONDITION

AP Panel Openings

AP Panel Openings

AP Metal Bldg Walkdoor-KD-Others

AP Panel - Metal Building Walkdoor -- Knocked-Down (by Chief) or Door Not by Chief Refer to Order Documents for Doors by Chief

#12-14 X 1 1/4" PANCAKE HEAD FASTENER (36" C.C.)

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL

BL

ZEE GIRT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP.

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT1)

1

4 "

1

2 "

LINER COVER TRIM (LCT2)

DOOR FRAME

1

4 "

OPENING HEIGHT

CEE HEADER

1

2 "

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALKDOOR HEADER TRIM DETAILS

LINER COVER TRIM (LCT1) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

JAMB

OPENING WIDTH

4 1/4"

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT2) (AS REQUIRED)

**#12-14 X 1 1/4" (12" C.C.)

DOOR FRAME

DOOR FRAME DOOR FRAME

NOTCH WALL PANEL FOR EXTENSION OF TRIM

BL

JAMB TRIM (JTA)

WALL PANEL

1/8"

SHEETING SUPPORT (SSP)

JAMB TRIM (JTA)

1/4-14 X 7/8" (12" C.C.)

TRIM DETAIL AT CORNER

WALKDOOR JAMB TRIM DETAILS

AP Metal Bldg Walkdoor-PA-SF

AP Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief

#12-14 X 1 1/4" PANCAKE HEAD FASTENER (36" C.C.)

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE

BL

WALL PANEL HEADER TRIM WITH TROUGH (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

ZEE GIRT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1

4 "

1

2 "

DOOR FRAME

1

4 "

OPENING HEIGHT

CEE HEADER

1

2 "

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR HEADER TRIM DETAILS

Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)

DOOR SUB FRAME

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

4 1/4"

HEADER TRIM WITH TROUGH (HTT)

**#12-14 X 1 1/4" (12" C.C.)

DOOR FRAME

DOOR FRAME

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

BL

JAMB TRIM (JTA)

DOOR FRAME

WALL PANEL

1/8"

SHEETING SUPPORT (SSP) 1/4-14 X 7/8" (12" C.C.)

JAMB TRIM (JTA)

TRIM DETAIL AT CORNER

PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR JAMB TRIM DETAILS

AP OHD or 3-Sided Opening

AP Panel - OHD or 3-Sided Opening

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) HEADER

BL

WALL PANEL

BL

**#12-14 X 1 1/4" (12" C.C.)

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

HEADER TRIM WITH TROUGH (HTT) DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

HEADER

INSIDE CLOSURE

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

DETAILS AT HEADER

1

4 "

JAMB

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

HEADER TRIM WITH TROUGH (HTT) DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

OPENING HEIGHT

BL

JAMB TRIM (JTA)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

DETAILS AT JAMB

TRIM DETAILS AT HEADER

Notes: ·

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

4 1/4"

JAMB

OPENING WIDTH

2 1/4"

HEADER TRIM WITH TROUGH (HTT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

**#12-14 X 1 1/4" (12" C.C.)

BL

JAMB TRIM (JTA)

JAMB TRIM (JTA)

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

SHEETING SUPPORT (SSP)

TRIM DETAIL AT CORNER

TRIM DETAILS AT JAMBS

AP Window by Chief

AP Panel - Window by Chief

#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL HEADER TRIM WITH TROUGH (HTT)

Notes: ·

ZEE GIRT

Drill Ø1/8" holes for Blind Rivets. Drill Ø3/16" holes for Bulbtite Rivets.

BL

·

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

4 1/4"

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1

4 "

HEADER TRIM WITH TROUGH (HTT)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

OPENING HEIGHT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

JAMB TRIM (JTA)

LINER COVER TRIM (LCT2)

JAMB TRIM (JT)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion. 1 4 "

WINDOW BY CHIEF

LINER COVER TRIM (LCT1)

4 1/4"

CEE HEADER

CHIEF WINDOW HEADER TRIM DETAILS

TRIM DETAIL AT CORNER

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

BL

JAMB

WINDOW BY CHIEF

LINER COVER TRIM (LCT1)

LINER COVER TRIM (LCT2)

OPENING WIDTH

2 1/4"

LINER COVER TRIM (LCT1)

JAMB TRIM (JT)

OPENING HEIGHT

LINER COVER TRIM (LCT2)

**#12-14 X 1 1/4" (12" C.C.)

INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.) WALL PANEL

BL

WINDOW BY CHIEF

GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

WALL PANEL

URETHANE CAULK (NOT BY CHIEF) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) SHEETING SUPPORT (SSP)

1/4-14 X 7/8" (12" C.C.)

JAMB TRIM (JTA)

OPENING HEIGHT

CEE SILL

CHIEF WINDOW JAMB TRIM DETAILS

CHIEF WINDOW SILL TRIM DETAILS

AP Window or 4-Sided Opening w Jamb Trim–JT

AP Panel - Window Not by Chief or 4-Sided Opening with Jamb Trim – JT

Notes: ·

LINER COVER TRIM (LCT1)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT) JAMB

OPENING WIDTH

**#12-14 X 1 1/4" (12" C.C.)

OPENING WIDTH

2 1/4"

BL

JAMB

LINER COVER TRIM (LCT2)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

JAMB TRIM (JTA) SHEETING SUPPORT (SSP) LINER COVER TRIM (LCT2)

JAMB TRIM (JTA)

BL

FRAMED OPENING DETAILS AT JAMB

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

GIRT

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

TRIM DETAILS AT JAMB

1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)

BL

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE

ZEE GIRT

HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

WALL PANEL

OPENING

1

4 "

JAMB TRIM (JT)

HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

1

4 "

OPENING HEIGHT

GIRT/SILL

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

CEE HEADER

OPENING DETAILS AT HEADER AND SILL

TRIM DETAILS AT HEADER

4 1/4"

BL

LINER COVER TRIM (LCT2)

JAMB TRIM (JT)

OPENING HEIGHT

HEADER TRIM WITH TROUGH (HTT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)

JAMB TRIM (JTA)

JAMB TRIM (JT)

WALL PANEL

4 1/4"

GIRT/SILL

TRIM (JT) DETAILS AT SILL

TRIM DETAIL AT CORNER

AP Window or 4-Sided Opening w Sill Flashing–WFS

AP Panel - Window or 4-Sided Opening with Sill Flashing – WFS

Notes: ·

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

LINER COVER TRIM (LCT1)

1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)

OPENING WIDTH

**#12-14 X 1 1/4" (12" C.C.)

OPENING WIDTH

2 1/4"

JAMB

LINER COVER TRIM (LCT2)

JAMB

BL

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

LINER COVER TRIM (LCT2)

JAMB TRIM (JTA)

FRAMED OPENING DETAILS AT JAMB

JAMB TRIM (JTA) SHEETING SUPPORT (SSP)

BL

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

TRIM DETAILS AT JAMB

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) (TYP.)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

BL

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL

ZEE GIRT

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

OPENING

1

4 "

SILL TRIM FLASHING (WFS)

1

4 "

HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)

GIRT/SILL

OPENING HEIGHT

CEE HEADER

OPENING DETAILS AT HEADER AND SILL

TRIM DETAILS AT HEADER

4 1/4"

BL

LINER COVER TRIM (LCT1)

1/8" X 3/8" BLIND RIVET (12" C.C.)

SILL TRIM FLASHING (WFS)

OPENING HEIGHT

HEADER TRIM (HT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

1/4-14 X 7/8" (12" C.C.)

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)

JAMB TRIM (JTA)

SILL TRIM FLASHING (WFS)

WALL PANEL

4 1/4"

GIRT/SILL

TRIM DETAIL AT SILL (WFS)

TRIM DETAIL AT CORNER

AP Window or 4-Sided Opening w Trim Only

AP Panel - Window or 4-Sided Opening with Trim Only

BL

LINER COVER TRIM (LCT1)

FRAMING (NOT BY CHIEF)

**#12-14 X 1 1/4" (6" C.C.)

INSIDE CLOSURE WALL PANEL

OPENING WIDTH

HEADER TRIM WITH THROUGH (HTT)

**#12-14 X 1 1/4" (12" C.C.)

LINER COVER TRIM (LCT2)

1

4 "

BL

FRAMING (NOT BY CHIEF)

JAMB TRIM (JTA)

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

LINER COVER TRIM (LCT2) LINER COVER TRIM (LCT1) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

SHEETING SUPPORT (SSP)

OPENING HEIGHT

TRIM ONLY HEADER DETAILS

TRIM ONLY JAMB DETAILS

Notes: ·

BL

LINER COVER TRIM (LCT1)

LINER COVER TRIM (LCT2)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

JAMB TRIM (JT)

FRAMING (NOT BY CHIEF)

4 1/4"

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)

JAMB TRIM (JT)

WALL PANEL

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT1)

BL

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

1/8" X 3/8" BLIND RIVET (12" C.C.)

1/4-14 X 7/8" (12" C.C.)

JAMB TRIM (JTA)

SILL TRIM FLASHING (WFS) INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.)

FRAMING (NOT BY CHIEF)

SILL TRIM ( JT / WFS)

SILL TRIM (WFS)

WALL PANEL

4 1/4" TRIM DETAIL AT CORNER

TRIM DETAILS AT SILL

CS Panel Openings

CS Panel Openings

CS Metal Bldg Walkdoor-KD-Others

CS Panel - Metal Building Walkdoor -- Knocked-Down (by Chief) or Door Not by Chief Refer to Order Documents for Doors by Chief

#12-14 X 1 1/4" PANCAKE HEAD FASTENER (36" C.C.)

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE WALL PANEL

BL

ZEE GIRT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP.

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT1)

1

4 "

1

2 "

LINER COVER TRIM (LCT2)

DOOR FRAME

1

4 "

OPENING HEIGHT

CEE HEADER

1

2 "

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALKDOOR HEADER TRIM DETAILS

JAMB LINER COVER TRIM (LCT1) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

3" Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg. HEADER TRIM (HTT)

OPENING WIDTH

LINER COVER TRIM (LCT2) (AS REQUIRED)

DOOR FRAME

BL

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

DOOR FRAME

JAMB TRIM (JT)

WALL PANEL

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1/8"

**#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT)

COVER TRIM (COT)

JAMB TRIM (JT)

1/8" X 3/8" BLIND RIVET (18" C.C.)

TRIM DETAIL AT CORNER

WALKDOOR JAMB TRIM DETAILS

CS Metal Bldg Walkdoor-PA-SF

CS Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief

#12-14 X 1 1/4" PANCAKE HEAD FASTENER (36" C.C.)

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE

BL

WALL PANEL HEADER TRIM WITH TROUGH (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

ZEE GIRT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1

4 "

1

2 "

DOOR FRAME

1

4 "

OPENING HEIGHT

CEE HEADER

1

2 "

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR HEADER TRIM DETAILS

Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

LINER COVER TRIM (LCT1 OR LCT2)(Field modify as req'd)

DOOR SUB FRAME

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) TYP.

3"

HEADER TRIM WITH TROUGH (HTT)

DOOR FRAME

DOOR FRAME

BL

JAMB TRIM (JT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT)

1 8 "

COVER TRIM (COT)

JAMB TRIM (JT)

1/8" X 3/8" BLIND RIVET (18" C.C.)

TRIM DETAIL AT CORNER

PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR JAMB TRIM DETAILS

CS OHD or 3-Sided Opening

CS Panel - OHD or 3-Sided Opening

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) HEADER

BL

WALL PANEL

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

**#12-14 X 1 1/4" (12" C.C.)

HEADER TRIM WITH TROUGH (HTT) DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

BL

HEADER

INSIDE CLOSURE

DETAILS AT HEADER

1

4 "

JAMB

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

HEADER TRIM WITH TROUGH (HTT)

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

OPENING HEIGHT

BL

JAMB TRIM (JT)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

DETAILS AT JAMB

TRIM DETAILS AT HEADER

Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

JAMB

HEADER TRIM WITH TROUGH (HTT)

3"

OPENING WIDTH

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

BL

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT)

JAMB TRIM (JT)

COVER TRIM (COT)

JAMB TRIM (JT)

1/8" X 3/8" BLIND RIVET (18" C.C.)

TRIM DETAIL AT CORNER

TRIM DETAILS AT JAMBS

CS Window by Chief

CS Panel - Window by Chief

Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

ZEE GIRT

#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE WALL PANEL HEADER TRIM WITH TROUGH (HTT)

BL

3"

1

4 "

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

HEADER TRIM WITH TROUGH (HTT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

OPENING HEIGHT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) WINDOW BY CHIEF LINER COVER TRIM (LCT2) LINER COVER TRIM (LCT1) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

JAMB TRIM (JT)

JAMB TRIM (JT)

1

4 "

COVER TRIM (COT)

CEE HEADER

CHIEF WINDOW HEADER TRIM DETAILS

TRIM DETAIL AT CORNER

BL

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

WINDOW BY CHIEF

LINER COVER TRIM (LCT1)

JAMB

LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

JAMB TRIM (JT)

OPENING HEIGHT

OPENING WIDTH

3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY)

LINER COVER TRIM (LCT2)

INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.) WALL PANEL

1/8" X 3/8" BLIND RIVET (7'-0" C.C)

BL

GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) JAMB TRIM (JT)

WINDOW BY CHIEF

URETHANE CAULK (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (18" C.C.)

OPENING HEIGHT

CEE SILL

CHIEF WINDOW JAMB TRIM DETAILS

CHIEF WINDOW SILL TRIM DETAILS

CS Window or 4-Sided Opening w Jamb Trim–JT

CS Panel - Window Not by Chief or 4-Sided Opening with Jamb Trim – JT

Notes: ·

LINER COVER TRIM (LCT1)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH LINER COVER TRIM (LCT) JAMB

OPENING WIDTH

OPENING WIDTH

JAMB

LINER COVER TRIM (LCT2)

BL

JAMB TRIM (JT) 1/8" X 3/8" BLIND RIVET (18" C.C.) LINER COVER TRIM (LCT2)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

JAMB TRIM (JT)

BL

FRAMED OPENING DETAILS AT JAMB

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT)

HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

TRIM DETAILS AT JAMB

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

BL

**#12-14 X 1 1/4" (6" C.C.)

ZEE GIRT

INSIDE CLOSURE

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

LINER COVER TRIM (LCT1)

WALL PANEL

OPENING

1

4 "

JAMB TRIM (JT)

HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

GIRT/SILL

OPENING HEIGHT

CEE HEADER

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

OPENING DETAILS AT HEADER AND SILL

1

4 "

TRIM DETAILS AT HEADER

3"

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

LINER COVER TRIM (LCT2)

BL

HEADER TRIM WITH TROUGH (HTT)

JAMB TRIM (JT)

OPENING HEIGHT

COVER TRIM (COT)

JAMB TRIM (JT)

INSIDE CLOSURE **#12-14 X 1 1/4" (6 "C.C.) WALL PANEL

JAMB TRIM (JT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

3"

GIRT/SILL

TRIM (JT) DETAILS AT SILL

TRIM DETAIL AT CORNER

CS Window or 4-Sided Opening w Sill Flashing–WFS

CS Panel - Window Not by Chief or 4-Sided Opening with Sill Flashing – WFS

Notes: ·

Drill Ø1/8" holes for Blind Rivets.

LINER COVER TRIM (LCT1)

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH LINER COVER TRIM (LCT) JAMB

OPENING WIDTH

OPENING WIDTH

JAMB

BL

LINER COVER TRIM (LCT2)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

JAMB TRIM (JT)

LINER COVER TRIM (LCT2)

BL

FRAMED OPENING DETAILS AT JAMB

JAMB TRIM (JT) 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT)

HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

TRIM DETAILS AT JAMB

1/8" X 3/8" BLIND RIVET, 36" C.C.

BL

ZEE GIRT

**#12-14 X 1 1/4" (6" C.C.)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

INSIDE CLOSURE WALL PANEL

LINER COVER TRIM (LCT1)

OPENING

1

4 "

HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)

1

4 "

GIRT/SILL

OPENING HEIGHT

CEE HEADER

OPENING DETAILS AT HEADER AND SILL

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

TRIM DETAILS AT HEADER

3"

LINER COVER TRIM (LCT1)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

BL

SILL TRIM FLASHING (WFS)

1/8" X 3/8" BLIND RIVET (12" C.C.)

OPENING HEIGHT

HEADER TRIM WITH TROUGH (HTT)

1/4-14 X 7/8" (12" C.C.)

COVER TRIM (COT)

JAMB TRIM (JT)

INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.) WALL PANEL

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

SILL TRIM FLASHING (WFS)

GIRT/SILL

3"

TRIM DETAIL AT SILL (WFS)

TRIM DETAIL AT CORNER

CS Window or 4-Sided Opening w Trim Only

CS Panel - Window or 4-Sided Opening with Trim Only

BL

LINER COVER TRIM (LCT1)

FRAMING (NOT BY CHIEF)

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE WALL PANEL HEADER TRIM WITH TROUGH (HTT)

OPENING WIDTH

LINER COVER TRIM (LCT2)

1

4 "

BL

JAMB TRIM (JT)

FRAMING (NOT BY CHIEF)

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)

LINER COVER TRIM (LCT2) LINER COVER TRIM (LCT1) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

OPENING HEIGHT

TRIM ONLY HEADER DETAILS

TRIM ONLY JAMB DETAILS

Notes: ·

LINER COVER TRIM (LCT2)

BL

LINER COVER TRIM (LCT1)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

JAMB TRIM (JT)

FRAMING (NOT BY CHIEF)

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.) WALL PANEL

3"

JAMB TRIM (JT)

LINER COVER TRIM (LCT1)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

HEADER TRIM WITH TROUGH (HTT)

BL

SILL TRIM FLASHING (WFS)

1/8" X 3/8" BLIND RIVET (12" C.C.)

JAMB TRIM (JT)

COVER TRIM (COT)

1/4-14 X 7/8" (12" C.C.)

INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

TRIM AT SILL (JT/ WFS)

SILL TRIM (WFS)

WALL PANEL

3"

TRIM DETAILS AT SILL

TRIM DETAIL AT CORNER

Wainscot - Lapped

Wainscot Lapped

T19.Wainscot Lapped at Zee w A-20

BL

UPPER WALL PANEL

RAKE ANGLE (A-20)

#12-14 X 1 1/4" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)

(2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

XXX'-X"

3" 3"

WAINSCOT GIRT(WINDOW SILL HEIGHT) WAINSCOT PANEL

T19

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED

T21.Wainscot Lapped HRC

BL

UPPER WALL PANEL

RAKE ANGLE (A-20) #12-14 X 1 1/4"

(6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-24 X 1 1/2" (36" C.C.) (UPPER WALL PANEL COLOR)

XXX'-X"

3" 3"

WAINSCOT GIRT (WINDOW SILL HEIGHT) WAINSCOT PANEL

T21

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED

T22.Wainscot Lapped Zee

BL

UPPER WALL PANEL

WAINSCOT GIRT OR SILL XXX'-X"

3" 3"

#12-14 X 1 1/4" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)

WAINSCOT PANEL

T22

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED

Wainscot Lapped at Sill

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL

WAINSCOT GIRT (WINDOW SILL HEIGHT) (2) #12-14 X 1 1/4" (36 "C.C.) (UPPER WALL PANEL COLOR) RAKE ANGLE (A-20)

6" PANEL LAP

XXX'-X"

WAINSCOT PANEL

Wainscot Lapped Mid-wall at Cee

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL

BL

WAINSCOT GIRT (TYP)

3" 3"

XXX'-X"

WAINSCOT PANEL

3" 3"

XXX'-X"

FULL WAINSCOT COLOR

LOWER WALL PANEL

Wainscot Lapped Mid-wall at Zee

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL

BL

WAINSCOT GIRT (TYP)

3" 3"

XXX'-X"

WAINSCOT PANEL

3" 3"

XXX'-X"

FULL WAINSCOT COLOR

LOWER WALL PANEL

Wainscot - No Lap (w WTT Trim)

Wainscot No Lap (w WTT Trim)

T15.Wainscot No Lap WTT at Cee

UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE

BL

#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

XXX'-X"

WAINSCOT GIRT OR SILL INSIDE CLOSURE WAINSCOT PANEL

T15

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED

T17.Wainscot No Lap WTT at HRC

UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE

BL

#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-24 X 1 1/2" (36" C.C.) (UPPER WALL PANEL COLOR)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

XXX'-X"

WAINSCOT GIRT OR SILL (HRC)

#12-24 X 1 1/2" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)

INSIDE CLOSURE WAINSCOT PANEL

T17

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED

T18.Wainscot No Lap WTT at Zee

BL

UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE

#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

XXX'-X"

WAINSCOT GIRT OR SILL INSIDE CLOSURE WAINSCOT PANEL

T18

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED

Wainscot No Lap WTT at Sill w Window by Chief

UPPER WALL PANEL (BEYOND) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) (BEYOND)

BL

JAMB TRIM (JT) CHIEF WINDOW

WAINSCOT GIRT or SILL

XXX'-X"

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) CAULK (NOT BY CHIEF)

WAINSCOT PANEL INSIDE CLOSURE

SECTION CUT THROUGH SILL OF CHIEF WINDOW AT WAINSCOT

Wainscot No Lap WTT Mid-Wall at Cee

UPPER WALL PANEL

WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR)

INSIDE CLOSURE

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

(2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

WAINSCOT GIRT (TYP)

1

4 "

XXX'-X"

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

WAINSCOT PANEL INSIDE CLOSURE INSIDE CLOSURE

RAKE ANGLE (A-20) (TYP) (2) #12-14 X 1 1/4" (36" C.C.) (LOWER WALL PANEL COLOR)

1

4 "

FULL WAINSCOT COLOR

XXX'-X"

WAINSCOT TRANSITION TRIM (WTT) (WALL COLOR)

INSIDE CLOSURE

LOWER WALL PANEL

Wainscot No Lap WTT Mid-Wall at Zee

UPPER WALL PANEL

WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR)

INSIDE CLOSURE

1

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

(2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

WAINSCOT GIRT (TYP)

1

4 "

XXX'-X"

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

WAINSCOT PANEL INSIDE CLOSURE INSIDE CLOSURE

RAKE ANGLE (A-20) (TYP) (2) #12-14 X 1 1/4" (36" C.C.) (LOWER WALL PANEL COLOR)

1

4 "

FULL WAINSCOT COLOR

XXX'-X"

WAINSCOT TRANSITION TRIM (WTT) (WALL COLOR)

INSIDE CLOSURE

LOWER WALL PANEL

Base Conditions

Base Conditions

Base Trim NONE-Lap

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C.for AP PANEL)

MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

INSIDE CLOSURE

1 1 2 "

CONCRETE (NOT BY CHIEF)

NO BASE TRIM FINISH FLOOR

Y1

Base Trim NONE-No Lap

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

INSIDE CLOSURE

CONCRETE (NOT BY CHIEF)

NO BASE TRIM FINISH FLOOR

Y1

Base Trim NONE-Notch

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF)

BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

INSIDE CLOSURE

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

1 1 2 "

CONCRETE (NOT BY CHIEF)

NO BASE TRIM FINISH FLOOR

Y1

Base Trim Simple L BT-Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

BL

#12-14 X 1 1/4" ( 6" C.C. for CS PANEL) (12" C.C. for AP PANEL) MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall

INSIDE CLOSURE

Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

1

4 "

1 1 2 "

BASE TRIM (BT)

CONCRETE (NOT BY CHIEF)

BASE TRIM (BT) FINISH FLOOR

Y1

Base Trim Simple L BT-No Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF)

INSIDE CLOSURE

BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

1

4 "

BASE TRIM (BT)

CONCRETE (NOT BY CHIEF)

BASE TRIM (BT) FINISH FLOOR

Y1

Base Trim Simple L BT-Notch

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF)

BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

INSIDE CLOSURE

1

4 "

BASE TRIM (BT)

1 1 2 "

CONCRETE (NOT BY CHIEF)

BASE TRIM (BT) FINISH FLOOR

Y1

Base Trim w Drip Edge BTN-Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

BL

WALL PANEL #12-14 X 1 1/4"

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall

INSIDE CLOSURE

Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

1

4 "

1 1 2 "

BASE TRIM (BTN)

CONCRETE (NOT BY CHIEF)

BASE TRIM (BTN) FINISH FLOOR

Y1

Base Trim w Drip Edge BTN-No Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF)

INSIDE CLOSURE

BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

1

4 "

BASE TRIM (BTN)

CONCRETE (NOT BY CHIEF)

BASE TRIM (BTN) FINISH FLOOR

Y1

Base Trim w Drip Edge BTN-Notch

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

INSIDE CLOSURE

1

4 "

BASE TRIM (BTN)

1 1 2 "

CONCRETE (NOT BY CHIEF)

BASE TRIM (BTN) FINISH FLOOR

Y1

Base Trim w Drip Edge Vertical BTNV-Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL #12-14 X 1 1/4"

BL

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall

INSIDE CLOSURE

Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

1

4 "

1 1 2 "

BASE TRIM (BTNV)

CONCRETE (NOT BY CHIEF)

BASE TRIM (BTNV) FINISH FLOOR

Y1

Base Trim w Drip Edge Vertical BTNV-No Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF)

INSIDE CLOSURE

BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

1

4 "

BASE TRIM (BTNV) CONCRETE (NOT BY CHIEF)

BASE TRIM (BTNV) FINISH FLOOR

Y1

Base Trim w Drip Edge Vertical BTNV-Notch

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF)

BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

INSIDE CLOSURE

1

4 "

BASE TRIM (BTNV)

1 1 2 "

CONCRETE (NOT BY CHIEF)

BASE TRIM (BTNV) FINISH FLOOR

Y1

Base Trim w Return Leg BTM-Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL #12-14 X 1 1/4"

BL

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL) MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

BASE TRIM (BTM)

INSIDE CLOSURE

1

4 "

1 1 2 "

BASE TRIM (BTM)

BASE TRIM PLUG (BTMCL OR BTMCR)

CONCRETE (NOT BY CHIEF)

(3) 1/8" X 3/8" BLIND RIVETS

BASE TRIM (BTM) FINISH FLOOR

Y1

Base Trim w Return Leg BTM-No Lap

Reference notes: · Use 1/8" x 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" x 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALL PANEL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

MASTIC (NOT BY CHIEF)

BASE TRIM (BTM)

BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

INSIDE CLOSURE

1

4 "

BASE TRIM (BTM)

BASE TRIM PLUG (BTMCL OR BTMCR)

CONCRETE (NOT BY CHIEF)

(3) 1/8" X 3/8" BLIND RIVETS

BASE TRIM (BTM) FINISH FLOOR

Made with FlippingBook - professional solution for displaying marketing and sales documents online