Wall Panel and Trim

Animated publication

Wall Panel and Trim Sections & Details

All details downloadable in .dwg and .pdf

Table of Contents

Wall Panel Details AP Wall Details CS Wall Details AP Panel Openings AP Metal Bldg Walkdoor-KD-Others AP Metal Bldg Walkdoor-PA-SF AP OHD or 3-Sided Opening AP Window by Chief

AP Window or 4-Sided Opening w Jamb Trim–JT AP Window or 4-Sided Opening w Sill Flashing–WFS AP Window or 4-Sided Opening w Trim Only CS Panel Openings CS Metal Bldg Walkdoor-KD-Others CS Metal Bldg Walkdoor-PA-SF CS OHD or 3-Sided Opening CS Window by Chief CS Window or 4-Sided Opening w Jamb Trim-JT CS Window or 4-Sided Opening w Sill Flashing-WFS CS Trim Only 4-Sided Opening w Jamb Trim-JT CS Trim Only 4-Sided Opening w Sill Flashing-WFS Wainscot - Lapped T19.Wainscot Lapped at Zee w A-20

T21.Wainscot Lapped HRC T22.Wainscot Lapped Zee Wainscot Lapped at Sill

Wainscot Lapped Mid-wall at Cee Wainscot Lapped Mid-wall at Zee Wainscot - No Lap (w WTT Trim)

T15.Wainscot No Lap WTT at Cee T17.Wainscot No Lap WTT at HRC T18.Wainscot No Lap WTT at Zee Wainscot No Lap WTT at Sill w Window by Chief

Wainscot No Lap WTT Mid-Wall at Cee Wainscot No Lap WTT Mid-Wall at Zee Base Conditions Base Trim NONE-Lap

Base Trim NONE-No Lap Base Trim NONE-Notch Base Trim Simple L BT-Lap Base Trim Simple L BT-No Lap

Table of Contents

Base Trim Simple L BT-Notch Base Trim w Drip Edge BTN-Lap Base Trim w Drip Edge BTN-No Lap Base Trim w Drip Edge BTN-Notch

Base Trim w Drip Edge Vertical BTNV-Lap Base Trim w Drip Edge Vertical BTNV-No Lap Base Trim w Drip Edge Vertical BTNV-Notch Base Trim w Return Leg BTM-Lap Base Trim w Return Leg BTM-No Lap Base Trim One Piece OPB Wallite Light Transmitting Panel

AP Wall AP Light Transmitting Panel w AP Liner Panel Horizontal Section AP Wall AP Light Transmitting Panel w CS Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w AP Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w CS Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w Full Height Liner CS Wall CS Light Transmitting Panel w AP Liner Panel Horizontal Section CS Wall CS Light Transmitting Panel w CS Liner Panel Horizontal Section CS Wall-CS Light Transmitting Panel or AP Wall-AP LTP w Full Height Liner

Wall Panel Details

Wall Panel Details

AP Wall Details

AP WALL PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.

12"

NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Insulation has not been shown for clarity. · Blanket insulation must be trimmed above the bottom of panel to prevent water from "WICKING" into the insulation. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · #12-14 X 1 1/4" Fastener spacing is (12" C.C.) unless otherwise noted. ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness ** #12-14 X 2", Blanket Insulation >4" thickness · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather.

Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")

STEEL LINE

BL

GIRT

Clip offset

RAKE ANGLE

WALL PANEL

TAPE MASTIC AT SIDELAPS, IF ORDERED ** #12-14 X 1 1/4 (12" C.C.)

**#12-14 X 1 1/4" (12" C.C.)

TOP OF PURLIN

NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.

**#12-14 X 1 1/4" (12" C.C.)

1"

BL

AP PANELING

Intermediate Girt Detail

STEEL LINE

Eave Height

BL

EAVE STRUT

WALL PANEL

BL

PANEL SIDELAP EAVE STRUT

Sidewall Eave Detail Low side shown. High Side Typical.

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

GIRT

12" (TYP.)

RISE

3" 3"

6"

MIN.

**#12-14 X 1 1/4" (12" C.C.)

WALL PANEL

BL

Panel Endlap Detail

* 1/4-14 X 7/8" (TYP.)

AP PANEL FASTENER INSTALLATION

AP PANEL AT GABLE END

1/4-14 X 7/8" (TYP.) (18" C.C.)

NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.

NOTES: ·

Field cut panel if required for corner trim.

· Corner Angle connection/fasteners, refer to Girt Corner Detail.

GIRT

12" (TYP.)

SHEETING SUPPORT (SSP)

TAPE MASTIC CENTERED ON HIGH RIB IS SHOWN THOUGH IS AN ORDER OPTION. REFER TO WALL MASTIC REQUIREMENTS IN ORDERED OPTIONS ON DRAWING COVER PAGE (C1)

1/4-14 X 7/8" (18" C.C.)

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

STEEL LINE

CORNER TRIM (CTA)

RETURN LEG

L

B

* 18" (TYP.)

CORNER ANGLE (A-20)

PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)

12" (TYP.)

AP PANEL 1/4-14 X 7/8" (12" C.C.) (TYP.)

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

2 1/2"

2 1/2"

1 1/2"

BASE MEMBER

TAPE MASTIC AT SIDELAPS, IF ORDERED

B

L

AP PANEL INSTALLATION

AP PANEL SIDE LAPS

AP PANEL STANDARD CORNER CONDITION

CS Wall Details

CS WALL PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.

6"

3"

NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Insulation has not been shown for clarity. · Blanket insulation must be trimmed above the bottom of panel to prevent water from "WICKING" into the insulation. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · #12-14 X 1 1/4" Fastener spacing is (12" C.C.) unless otherwise noted. ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness ** #12-14 X 2", Blanket Insulation >4" thickness · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather.

Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")

STEEL LINE

GIRT

Clip offset

WALL PANEL

RAKE ANGLE

TAPE MASTIC AT SIDELAPS, IF ORDERED ** #12-14 X 1 1/4 (6" C.C.)

**#12-14 X 1 1/4" (12" C.C.)

TOP OF PURLIN

NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.

**#12-14 X 1 1/4" (6" C.C.)

1"

BL

CS PANELING

Intermediate Girt Detail

STEEL LINE

Eave Height

EAVE STRUT

WALL PANEL

BL

PANEL SIDELAP EAVE STRUT

Sidewall Eave Detail Low side shown. High Side Typical.

GIRT

6" (TYP.)

3"

** #12-14 X 1 1/4" (6" C.C.) (TYP.)

RISE

3" 3"

6"

MIN.

**#12-14 X 1 1/4" (6" C.C.)

WALL PANEL

BL

1/4-14 X 7/8" (TYP.) (18" C.C.)

Panel Endlap Detail

* 1/4-14 X 7/8" (TYP.)

CS PANEL FASTENER INSTALLATION

CS PANEL AT GABLE END

NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.

NOTES: ·

Field cut panel if required for corner trim.

· Corner Angle connection/fasteners, refer to Girt Corner Detail. · Connection of panel to structure at corner is by the corner trim fasteners.

GIRT

12" (TYP.)

** #12-14 X 1 1/4" (12" C.C.) (TYP.)

1/4-14 X 7/8" (18" C.C.)

CORNER TRIM (CT)

STEEL LINE

CORNER ANGLE (A-20)

RETURN LEG

PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)

* 18" (TYP.)

L

B

TAPE MASTIC CENTERED ON HIGH RIB IS SHOWN THOUGH IS AN ORDER OPTION. REFER TO WALL MASTIC REQUIREMENTS IN ORDERED OPTIONS ON DRAWING COVER PAGE (C1)

6" (TYP.)

3"

CS PANEL

* 1/4-14 X 7/8" (TYP.)

** #12-14 X 1 1/4" (6" C.C.) (TYP.)

2 1/2"

1 1/2"

#12-14 X 1 1/4 (12" C.C.) (TYP.)

BASE MEMBER

B

L

CS PANEL INSTALLATION

CS PANEL SIDE LAPS

CS PANEL STANDARD CORNER CONDITION

AP Panel Openings

AP Panel Openings

AP Metal Bldg Walkdoor-KD-Others

AP Panel - Metal Building Walkdoor -- Knocked-Down (by Chief) or Door Not by Chief Refer to Order Documents for Doors by Chief

#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL

BL

ZEE GIRT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP.

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT1)

1

4 "

1

2 "

LINER COVER TRIM (LCT2)

DOOR FRAME

1

4 "

OPENING HEIGHT

CEE HEADER

1

2 "

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALKDOOR HEADER TRIM DETAILS

LINER COVER TRIM (LCT1) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

JAMB

OPENING WIDTH

4 1/4"

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT2) (AS REQUIRED)

**#12-14 X 1 1/4" (12" C.C.)

DOOR FRAME

NOTCH WALL PANEL FOR EXTENSION OF TRIM

DOOR FRAME DOOR FRAME

BL

JAMB TRIM (JTA)

WALL PANEL

1/8"

SHEETING SUPPORT (SSP)

JAMB TRIM (JTA)

1/4-14 X 7/8" (12" C.C.)

1/8"

TRIM DETAIL AT CORNER

WALKDOOR JAMB TRIM DETAILS

AP Metal Bldg Walkdoor-PA-SF

AP Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief

#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE

BL

WALL PANEL HEADER TRIM WITH TROUGH (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

ZEE GIRT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1

4 "

1

2 "

DOOR FRAME

1

4 "

OPENING HEIGHT

CEE HEADER

1

2 "

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR HEADER TRIM DETAILS

Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)

DOOR SUB FRAME

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

4 1/4"

HEADER TRIM WITH TROUGH (HTT)

**#12-14 X 1 1/4" (12" C.C.)

DOOR FRAME

DOOR FRAME

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

BL

JAMB TRIM (JTA)

DOOR FRAME

WALL PANEL

1/8"

SHEETING SUPPORT (SSP) 1/4-14 X 7/8" (12" C.C.)

JAMB TRIM (JTA)

1/8"

TRIM DETAIL AT CORNER

PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR JAMB TRIM DETAILS

AP OHD or 3-Sided Opening

AP Panel - OHD or 3-Sided Opening

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) HEADER

BL

WALL PANEL

BL

**#12-14 X 1 1/4" (12" C.C.)

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

HEADER TRIM WITH TROUGH (HTT) DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

HEADER

INSIDE CLOSURE

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

DETAILS AT HEADER

1

4 "

JAMB

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

HEADER TRIM WITH TROUGH (HTT) DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

OPENING HEIGHT

BL

JAMB TRIM (JTA)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

DETAILS AT JAMB

TRIM DETAILS AT HEADER

Notes: ·

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

4 1/4"

JAMB

OPENING WIDTH

2 1/4"

HEADER TRIM WITH TROUGH (HTT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

**#12-14 X 1 1/4" (12" C.C.)

BL

JAMB TRIM (JTA)

JAMB TRIM (JTA)

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

SHEETING SUPPORT (SSP)

TRIM DETAIL AT CORNER

TRIM DETAILS AT JAMBS

AP Window by Chief

AP Panel - Window by Chief

#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL HEADER TRIM WITH TROUGH (HTT)

Notes: ·

ZEE GIRT

Drill Ø1/8" holes for Blind Rivets. Drill Ø3/16" holes for Bulbtite Rivets.

BL

·

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

4 1/4"

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

1

4 "

HEADER TRIM WITH TROUGH (HTT)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

OPENING HEIGHT

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

JAMB TRIM (JTA)

LINER COVER TRIM (LCT2)

JAMB TRIM (JT)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion. 1 4 "

WINDOW BY CHIEF

LINER COVER TRIM (LCT1)

4 1/4"

CEE HEADER

CHIEF WINDOW HEADER TRIM DETAILS

TRIM DETAIL AT CORNER

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

BL

JAMB

WINDOW BY CHIEF

LINER COVER TRIM (LCT1)

LINER COVER TRIM (LCT2)

OPENING WIDTH

2 1/4"

LINER COVER TRIM (LCT1)

JAMB TRIM (JT)

OPENING HEIGHT

LINER COVER TRIM (LCT2)

**#12-14 X 1 1/4" (12" C.C.)

INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.) WALL PANEL

BL

WINDOW BY CHIEF

GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

WALL PANEL

URETHANE CAULK (NOT BY CHIEF)

1/4-14 X 7/8" (12" C.C.)

JAMB TRIM (JTA)

3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) SHEETING SUPPORT (SSP)

OPENING HEIGHT

CEE SILL

CHIEF WINDOW JAMB TRIM DETAILS

CHIEF WINDOW SILL TRIM DETAILS

AP Window or 4-Sided Opening w Jamb Trim–JT

AP Panel - Window Not by Chief or 4-Sided Opening with Jamb Trim – JT

Notes: ·

LINER COVER TRIM (LCT1)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT) JAMB

OPENING WIDTH

**#12-14 X 1 1/4" (12" C.C.)

OPENING WIDTH

2 1/4"

BL

JAMB

LINER COVER TRIM (LCT2)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

JAMB TRIM (JTA) SHEETING SUPPORT (SSP) LINER COVER TRIM (LCT2)

JAMB TRIM (JTA)

BL

FRAMED OPENING DETAILS AT JAMB

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

GIRT

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

TRIM DETAILS AT JAMB

1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)

BL

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE

ZEE GIRT

HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

WALL PANEL

OPENING

1

4 "

JAMB TRIM (JT)

HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

1

4 "

OPENING HEIGHT

GIRT/SILL

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

CEE HEADER

OPENING DETAILS AT HEADER AND SILL

TRIM DETAILS AT HEADER

4 1/4"

BL

LINER COVER TRIM (LCT2)

JAMB TRIM (JT)

OPENING HEIGHT

HEADER TRIM WITH TROUGH (HTT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)

JAMB TRIM (JTA)

JAMB TRIM (JT)

WALL PANEL

4 1/4"

GIRT/SILL

TRIM (JT) DETAILS AT SILL

TRIM DETAIL AT CORNER

AP Window or 4-Sided Opening w Sill Flashing–WFS

AP Panel - Window or 4-Sided Opening with Sill Flashing – WFS

Notes: ·

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

LINER COVER TRIM (LCT1)

1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)

OPENING WIDTH

**#12-14 X 1 1/4" (12" C.C.)

OPENING WIDTH

2 1/4"

JAMB

LINER COVER TRIM (LCT2)

JAMB

BL

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

LINER COVER TRIM (LCT2)

JAMB TRIM (JTA)

FRAMED OPENING DETAILS AT JAMB

JAMB TRIM (JTA) SHEETING SUPPORT (SSP)

BL

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

TRIM DETAILS AT JAMB

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) (TYP.)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

BL

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL

ZEE GIRT

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

OPENING

1

4 "

SILL TRIM FLASHING (WFS)

1

4 "

HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)

GIRT/SILL

OPENING HEIGHT

CEE HEADER

OPENING DETAILS AT HEADER AND SILL

TRIM DETAILS AT HEADER

4 1/4"

BL

LINER COVER TRIM (LCT1)

1/8" X 3/8" BLIND RIVET (12" C.C.)

SILL TRIM FLASHING (WFS)

OPENING HEIGHT

HEADER TRIM (HT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

1/4-14 X 7/8" (12" C.C.)

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.) WALL PANEL

JAMB TRIM (JTA)

SILL TRIM FLASHING (WFS)

4 1/4"

GIRT/SILL

TRIM DETAIL AT SILL (WFS)

TRIM DETAIL AT CORNER

AP Window or 4-Sided Opening w Trim Only

AP Panel - Window or 4-Sided Opening with Trim Only

BL

LINER COVER TRIM (LCT1)

FRAMING (NOT BY CHIEF)

**#12-14 X 1 1/4" (6" C.C.)

INSIDE CLOSURE WALL PANEL

OPENING WIDTH

HEADER TRIM WITH THROUGH (HTT)

**#12-14 X 1 1/4" (12" C.C.)

LINER COVER TRIM (LCT2)

1

4 "

BL

FRAMING (NOT BY CHIEF)

JAMB TRIM (JTA)

WALL PANEL 1/4-14 X 7/8" (12" C.C.)

LINER COVER TRIM (LCT2) LINER COVER TRIM (LCT1) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

SHEETING SUPPORT (SSP)

OPENING HEIGHT

TRIM ONLY HEADER DETAILS

TRIM ONLY JAMB DETAILS

Notes: ·

BL

LINER COVER TRIM (LCT1)

LINER COVER TRIM (LCT2)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

JAMB TRIM (JT)

FRAMING (NOT BY CHIEF)

4 1/4"

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)

JAMB TRIM (JT)

WALL PANEL

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT1)

BL

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

1/8" X 3/8" BLIND RIVET (12" C.C.)

1/4-14 X 7/8" (12" C.C.)

JAMB TRIM (JTA)

SILL TRIM FLASHING (WFS) INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.)

FRAMING (NOT BY CHIEF)

SILL TRIM ( JT / WFS)

SILL TRIM (WFS)

WALL PANEL

4 1/4" TRIM DETAIL AT CORNER

TRIM DETAILS AT SILL

CS Panel Openings

CS Panel Openings

CS Metal Bldg Walkdoor-KD-Others

CS Panel - Metal Building Walkdoor -- Knocked-Down (by Chief) or Door Not by Chief Refer to Order Documents for Doors by Chief

Installation Steps: 1. Install Wrap Plate. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Door. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closure. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

HEADER TRIM (HTT)

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

1" PANEL SLIT

INSIDE CLOSURE

JAMB TRIM (JT)

For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

1" SLIT

2" X 1/4" NOTCH

2" JAMB TRIM NOTCH

COVER TRIM (COT)

DOOR FRAME

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

TRIM DETAIL AT CORNERS

WALL PANEL SLIT

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

WALL PANEL

#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)

BL

OPENING WIDTH

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE HEADER TRIM (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

ZEE GIRT

JAMB

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP. SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

NOMINAL DOOR OPENING

* 1 4 "

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)

DOOR FRAME

BL

JAMB TRIM (JT)

1

2 " MIN.

WALL PANEL

CUT RIB AS NEEDED

***1/8"-3/4"

DOOR FRAME

OPENING HEIGHT

**#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)

NOMINAL

*** Locate JT/COT/HTT trim

DOOR OPENING

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

assembly to cover door frame avoiding interference with latch, door and hinges.

CEE HEADER

WALKDOOR HEADER TRIM DETAILS

WALKDOOR JAMB TRIM DETAILS

CS Metal Bldg Walkdoor-PA-SF

CS Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief

Installation Steps: 1. Install Wrap Plate. 2. Door. 3. Jamb Trim (JT) with notch at header. 4. Header Trim (HTT). 5. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure. 7. Cover Trim (COT). 8. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

HEADER TRIM (HTT)

1" PANEL SLIT

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

INSIDE CLOSURE

For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

JAMB TRIM (JT)

1" SLIT

2" X 1/4" NOTCH

2" JAMB TRIM NOTCH

COVER TRIM (COT)

DOOR FRAME

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

WALL PANEL

#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)

BL

OPENING WIDTH

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE HEADER TRIM (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

ZEE GIRT

DOOR SUBFRAME

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP. SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

NOMINAL DOOR OPENING

* 1 4 "

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)

DOOR FRAME

BL

JAMB TRIM (JT)

1

2 " MIN.

WALL PANEL

CUT RIB AS NEEDED

***1/8"-3/4"

DOOR FRAME

OPENING HEIGHT

**#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)

NOMINAL

*** Locate JT/COT/HTT trim

DOOR OPENING

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

assembly to cover door frame avoiding interference with latch, door and hinges.

CEE HEADER

WALKDOOR HEADER TRIM DETAILS

WALKDOOR JAMB TRIM DETAILS

CS OHD or 3-Sided Opening

CS Panel - OHD or 3-Sided Opening

Installation Steps: 1. Door Trim (DT), if applicable. 2. Jamb Trim (JT) with notch at header. 3. Header Trim (HTT). 4. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closure. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

HEADER TRIM (HTT)

1" PANEL SLIT

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

INSIDE CLOSURE

For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

JAMB TRIM (JT)

1" SLIT

2" X 1/4" NOTCH

2" JAMB TRIM NOTCH

DOOR TRIM (DT) OPTIONAL. REFER TO PANEL DRAWINGS.

COVER TRIM (COT)

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

WALL PANEL

BL

OPENING WIDTH

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE

JAMB

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

HEADER

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

HEADER TRIM (HTT)

* 1 4 "

BL

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

JAMB TRIM (JT)

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)

DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS

CUT RIB AS NEEDED

OPENING HEIGHT

For Walkdoors to avoidinterference with latch, door, or hinges, hold JT/COT/HTT trim assembly back from jamb max 3/4", as necessary

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

WALKDOOR HEADER TRIM DETAILS

WALKDOOR JAMB TRIM DETAILS

CS Window by Chief

CS Panel - Window by Chief

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Window with Bulbtite. 4. Sill Jamb Trim (JT), slit and fold up at jamb. 5. Jamb Trim (JT) with notch at header. 6. Header Trim (HTT). 7. Notch and slit wall panel. 8. Place wall panel over trims with foam inside closures. 9. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)

LINER COVER TRIMS

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

1" SLIT

2" X 1/4" NOTCH

3" TO FLAT OF JAMB TRIM

2" JAMB TRIM NOTCH

COVER TRIM (COT)

SILL JAMB TRIM (JT)

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT (Typical at Sill)

TRIM DETAIL AT CORNERS

(Window not Shown)

ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) JAMB 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

**#12-14 X 1 1/4" (6" C.C.)

LINER COVER TRIM (LCT1)

CEE HEADER

INSIDE CLOSURE

OPENING WIDTH

* 1 4 "

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

HEADER TRIM (HTT) WINDOW BY CHIEF URETHANE CAULK (NOT BY CHIEF)

LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

BL

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT) * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

**#12-14 X 1 1/4" (12" C.C.) WALL PANEL

OPENING

JAMB TRIM (JT)

CUT RIB AS NEEDED

URETHANE CAULK (NOT BY CHIEF)

1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)

URETHANE CAULK (NOT BY CHIEF)

SILL JAMB TRIM (JT) INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.)

GIRT/SILL

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

WALL PANEL (TYP.)

CHIEF WINDOW HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB

CS Window or 4-Sided Opening w Jamb Trim-JT

CS Panel - Window Not by Chief or 4-Sided Opening with Sill Jamb Trim – JT

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Jamb Trim (JT), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)

LINER COVER TRIMS

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

1" SLIT

2" X 1/4" NOTCH

3" TO FLAT OF JAMB TRIM

2" JAMB TRIM NOTCH

COVER TRIM (COT)

SILL JAMB TRIM (JT) NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

(Window not Shown)

ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (6" C.C.)

BL

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

LINER COVER TRIM (LCT1)

INSIDE CLOSURE

CEE HEADER

* 1 4 " * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

OPENING WIDTH

JAMB 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

HEADER TRIM (HTT)

LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

BL

**#12-14 X 1 1/4" (12" C.C.) WALL PANEL

JAMB TRIM (JT)

OPENING

CUT RIB AS NEEDED

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)

SILL JAMB TRIM (JT)

INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.)

GIRT/SILL

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

WALL PANEL (TYP.)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB

CS Window or 4-Sided Opening w Sill Flashing-WFS

CS Panel - Window Not by Chief or 4-Sided Opening with Sill Flashing – WFS

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Trim Flashing (WFS), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)

LINER COVER TRIMS

FIELD VERIFY WFS OFFSET

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

2" X 1/4" NOTCH

1" SLIT

3" TO FLAT OF JAMB TRIM

2" JAMB TRIM NOTCH

COVER TRIM (COT)

NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (12" C.C.)

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

(Window not Shown)

ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

**#12-14 X 1 1/4" (6" C.C.)

LINER COVER TRIM (LCT1)

INSIDE CLOSURE

CEE HEADER

* 1 4 "

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1/8" X 3/8" BLIND RIVET (3'-0" C.C.)

OPENING WIDTH

JAMB 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

LINER COVER TRIM (LCT2)

HEADER TRIM (HTT)

LINER COVER TRIM (LCT1)

GIRT/SILL INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.) WALL PANEL (TYP.) SILL TRIM FLASHING (WFS) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

BL

**#12-14 X 1 1/4" (12" C.C.) WALL PANEL

JAMB TRIM (JT)

OPENING

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) 1/8" X 3/8" BLIND RIVET (12" C.C.)

CUT RIB AS NEEDED

1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB

CS Trim Only 4-Sided Opening w Jamb Trim-JT

CS Panel - Trim Only 4-Sided Opening with Sill Jamb Trim – JT

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Jamb Trim (JT), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)

LINER COVER TRIMS

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

1" SLIT

2" X 1/4" NOTCH

3" TO FLAT OF JAMB TRIM

2" JAMB TRIM NOTCH

COVER TRIM (COT)

SILL JAMB TRIM (JT) NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

BL

FRAMING (NOT BY CHIEF)

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

**#12-14 X 1 1/4" (6" C.C.)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

LINER COVER TRIM (LCT1)

INSIDE CLOSURE

* 1 4 "

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

OPENING WIDTH

HEADER TRIM (HTT)

LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

BL

**#12-14 X 1 1/4" (12" C.C.) WALL PANEL

JAMB TRIM (JT)

OPENING

CUT RIB AS NEEDED

LINER COVER TRIM (LCT2)

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)

SILL JAMB TRIM (JT) INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.) WALL PANEL (TYP.)

FRAMING (NOT BY CHIEF)

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB

CS Trim Only 4-Sided Opening w Sill Flashing-WFS

CS Panel - Trim Only 4-Sided Opening with Sill Flashing – WFS

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Trim Flashing (WFS), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)

LINER COVER TRIMS

FIELD VERIFY WFS OFFSET

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

1" SLIT

2" X 1/4" NOTCH

3" TO FLAT OF JAMB TRIM

2" JAMB TRIM NOTCH

COVER TRIM (COT)

NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (12" C.C.)

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

BL

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

FRAMING (NOT BY CHIEF)

**#12-14 X 1 1/4" (6" C.C.)

LINER COVER TRIM (LCT1)

INSIDE CLOSURE

* 1 4 " * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

OPENING WIDTH

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

BL

**#12-14 X 1 1/4" (12" C.C.) WALL PANEL

JAMB TRIM (JT)

OPENING

LINER COVER TRIM (LCT2)

CUT RIB AS NEEDED

FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT) 1/8" x 3/8" BLIND RIVET (12" C.C.)

1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)

SILL TRIM FLASHING (WFS) INSIDE CLOSURE ** #12-14 X 1 1/4" (6" C.C.) WALL PANEL (TYP.)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB

Wainscot - Lapped

Wainscot Lapped

T19.Wainscot Lapped at Zee w A-20

BL

UPPER WALL PANEL

RAKE ANGLE (A-20)

#12-14 X 1 1/4" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)

(2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

XXX'-X"

3" 3"

WAINSCOT GIRT(WINDOW SILL HEIGHT) WAINSCOT PANEL

T19

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED

T21.Wainscot Lapped HRC

BL

UPPER WALL PANEL

RAKE ANGLE (A-20) #12-14 X 1 1/4"

(6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-24 X 1 1/2" (36" C.C.) (UPPER WALL PANEL COLOR)

XXX'-X"

3" 3"

WAINSCOT GIRT (WINDOW SILL HEIGHT) WAINSCOT PANEL

T21

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED

T22.Wainscot Lapped Zee

BL

UPPER WALL PANEL

WAINSCOT GIRT OR SILL XXX'-X"

3" 3"

#12-14 X 1 1/4" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)

WAINSCOT PANEL

T22

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED

Wainscot Lapped at Sill

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL

WAINSCOT GIRT (WINDOW SILL HEIGHT) (2) #12-14 X 1 1/4" (36 "C.C.) (UPPER WALL PANEL COLOR) RAKE ANGLE (A-20)

6" PANEL LAP

XXX'-X"

WAINSCOT PANEL

Wainscot Lapped Mid-wall at Cee

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL

BL

WAINSCOT GIRT (TYP)

3" 3"

XXX'-X"

WAINSCOT PANEL

3" 3"

XXX'-X"

FULL WAINSCOT COLOR

LOWER WALL PANEL

Wainscot Lapped Mid-wall at Zee

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL

BL

WAINSCOT GIRT (TYP)

3" 3"

XXX'-X"

WAINSCOT PANEL

3" 3"

XXX'-X"

FULL WAINSCOT COLOR

LOWER WALL PANEL

Wainscot - No Lap (w WTT Trim)

Wainscot No Lap (w WTT Trim)

T15.Wainscot No Lap WTT at Cee

UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE

BL

#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

XXX'-X"

WAINSCOT GIRT OR SILL INSIDE CLOSURE WAINSCOT PANEL

T15

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED

T17.Wainscot No Lap WTT at HRC

UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE

BL

#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-24 X 1 1/2" (36" C.C.) (UPPER WALL PANEL COLOR)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

XXX'-X"

WAINSCOT GIRT OR SILL (HRC)

#12-24 X 1 1/2" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)

INSIDE CLOSURE WAINSCOT PANEL

T17

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED

T18.Wainscot No Lap WTT at Zee

BL

UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE

#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

XXX'-X"

WAINSCOT GIRT OR SILL INSIDE CLOSURE WAINSCOT PANEL

T18

TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED

Wainscot No Lap WTT at Sill w Window by Chief

UPPER WALL PANEL (BEYOND) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) (BEYOND)

BL

JAMB TRIM (JT) CHIEF WINDOW

WAINSCOT GIRT or SILL

XXX'-X"

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) CAULK (NOT BY CHIEF)

WAINSCOT PANEL INSIDE CLOSURE

SECTION CUT THROUGH SILL OF CHIEF WINDOW AT WAINSCOT

Wainscot No Lap WTT Mid-Wall at Cee

UPPER WALL PANEL

WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR)

INSIDE CLOSURE

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

(2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)

WAINSCOT GIRT (TYP)

1

4 "

XXX'-X"

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

WAINSCOT PANEL INSIDE CLOSURE INSIDE CLOSURE

RAKE ANGLE (A-20) (TYP) (2) #12-14 X 1 1/4" (36" C.C.) (LOWER WALL PANEL COLOR)

1

4 "

FULL WAINSCOT COLOR

XXX'-X"

WAINSCOT TRANSITION TRIM (WTT) (WALL COLOR)

INSIDE CLOSURE

LOWER WALL PANEL

Made with FlippingBook - professional solution for displaying marketing and sales documents online